Using the CS400/CS405 Submersible Pressure Transducer with Campbell Scientific Dataloggers
3
3.3 Transient Protection
Campbell Scientific recommends transient surge protection for sensors installed
in lightning prone areas. No lightning protection is capable of withstanding a
direct hit, but surge protectors afford a degree of protection for near misses.
Surge protection can be provided by Campbell Scientific’s SVP48 Surge
Voltage Protector. When an electrical surge occurs, the surge protectors
involved may need to be replaced.
3.4 Temperature Fluctuations
Temperature fluctuations can be minimized by using a minimum cable burial
depth of six inches and a sensor submersion depth of one foot.
3.5 Sensor Connections
Datalogger
#7977 Resistor
E1 -----------------------------Purple
CS400/CS405
1H -----------------------------Yellow
Black ------------------- 1L -----------------------------Black
Red---------------------- 2H
Green ------------------- 2L
White ------------------- AG
Blue--------------------- G/ground
3.6 BDR320
BDR320
#7977 Resistor
EX-----------------------------Purple
CS400/CS405 --------------- CH1 ---------------------------Yellow
Black ------------------- CH2 ---------------------------Black
Red---------------------- CH3
Green ------------------- CH4
White ------------------- AG
Blue--------------------- G/ground
3.7 BDR301
The CS400/CS405 can be connected to the BDR301 by using a DES-2
Desiccant Box and replacing the DES-2's standard five-lead cable with a six-
lead cable terminated with a ten-pin military connector. Figure 3-1 shows the
DES-2 wiring format with placement of a #7977 resistor.