Typical accuracy
from 0 to 40 °C:
±3% RH over 0 to 90%
±5% RH over 90 to 100%
Typical Accuracy
from –40 to 0 °C
and 40 to 60 °C:
±5% RH over 0 to 90%
±7% RH over 90 to 100%
7. Installation
If you are programming your data logger with
Short Cut
, skip
(p. 6) and
Short Cut
does this work for you. See
(p. 2) for a
Short Cut
tutorial.
7.1 Wiring to data logger
CAUTION:
Always connect the blue wire to the data logger first, followed by the black, white, and clear
wires. Connect the brown (power) wire last.
Table 7-1: Wire color, function, and data logger connection
Wire color
Wire function
Data logger connection terminal
Black
Temperature signal
U configured for single-ended analog input
1
,
SE (single-ended, analog-voltage input)
White
Relative humidity signal
U configured for single-ended analog input,
SE
Blue
Power ground and
signal reference
G
Brown
Power
12V or SW12
Clear
EMF Shield
⏚
(analog ground)
1
U terminals are automatically configured by the measurement instruction.
HMP60 Temperature and Relative Humidity Probe
6