6. Specifications
Operating temperature:
–40 to 60 °C
Probe length:
7.1 cm (2.8 in)
Probe body diameter:
1.2 cm (0.47 in)
Filter:
0.2 μm Teflon membrane
Filter diameter:
1.2 cm (0.47 in)
Housing
Body material:
AISI 316 stainless steel
Filter cap material:
Chrome-coated ABS plastic
Classification:
IP65
Power consumption:
1 mA typical; 5 mA maximum
Supply voltage:
5 to 28 VDC
Settling time after power is
switched on:
1 s
Output signal range:
0 to 1 VDC
6.1 Temperature sensor
Sensor:
1000 Ω PRT, DIN 43760B
Temperature
measurement range:
–40 to 60 °C
Temperature accuracy:
±0.6 °C (–40 to 60 °C)
6.2 Relative humidity sensor
Sensor:
INTERCAP®
Relative humidity
measurement range:
0 to 100% non-condensing
HMP60 Temperature and Relative Humidity Probe