CS115 Barometric Pressure Sensor
9
;Turn off CS115
;
4: Do (P86)
1:
58*
Set Port 8* Low
5: If time is (P92)
1:
0
Minutes (Seconds --) into a
2:
60
Interval (same units as above)
3:
10
Set Output Flag High (Flag 0)
6: Real Time (P77)
1:
0110
Day,Hour/Minute (midnight = 0000)
7: Sample (P70)
1:
1
Reps
2:
1*
Loc [ P_mb ]
*Table 2 Program
02: 0.0000
Execution Interval (seconds)
*Table 3 Subroutines
End Program
-Input Locations-
1 P_mb
* Proper entries will vary with program and datalogger channel, and input location assignments.
5.1.3 Period Averaging Measurement Example for CR23X
EXAMPLE 3. Sample Program for CR23X
;{CR23X}
;
*Table 1 Program
01: 1
Execution Interval (seconds)
;Turn on CS115 one minute before the hour
;
1: If time is (P92)
1:
59
Minutes (Seconds --) into a
2:
60
Interval (same units as above)
3:
41*
Set Port 1* High
;Measure CS115 at the top of the hour
;
2: If time is (P92)
1:
0
Minutes (Seconds --) into a
2:
60
Interval (same units as above)
3:
30
Then Do