Section 5. Overview
96
required to form a complete circuit for voltage clamping devices internal to the
CR6.
5.9.3 Factory Calibration — Overview
Related Topics
•
Auto Self-Calibration — Overview
(p. 99)
•
Auto Self-Calibration — Details
(p. 412)
•
Auto Self-Calibration — Errors
(p. 565)
•
Offset Voltage Compensation
(p. 397)
•
Factory Calibration
(p. 96)
•
Factory Calibration or Repair Procedure
(p. 550)
The CR6 uses an internal voltage reference to routinely calibrate itself. Campbell
Scientific recommends factory recalibration as specified in
Maintenance —
Specifications
(p. 134).
If calibration services are required, see
Assistance
(p. 5).
5.9.4 Internal Battery — Overview
Related Topics:
•
Internal Battery — Quickstart
(p. 42)
•
Internal Battery — Details
(p. 547)
Warning
Misuse or improper installation of the internal lithium battery
can cause severe injury. Fire, explosion, and severe burns can result. Do
not recharge, disassemble, heat above 100 °C (212 °F), solder directly to
the cell, incinerate, or expose contents to water. Dispose of spent lithium
batteries properly.
The CR6 contains a lithium battery that operates the clock and powers SRAM
when the CR6 is not externally powered. Voltage of the battery is monitored from
the CR6
Status
table (
LithiumBattery
(p. 631))
. Replace the battery as directed in
Internal Battery — Details
(p. 547).
The lithium battery is not rechargeable. Its design is one of the safest available
and uses lithium thionyl chloride technology. Maximum discharge current is
limited to a few mA. It is protected from discharging excessive current to the
internal circuits (there is no direct path outside) with a 100 ohm resistor. The
design is UL listed. See:
http://www.tadiran-batterie.de/download/eng/LBR06Eng.pdf.
Содержание CR6 Series
Страница 2: ......
Страница 4: ......
Страница 6: ......
Страница 32: ......
Страница 36: ......
Страница 38: ......
Страница 76: ...Section 5 Overview 76 FIGURE 20 Half Bridge Wiring Example Wind Vane Potentiometer ...
Страница 80: ...Section 5 Overview 80 FIGURE 23 Pulse Input Wiring Example Anemometer ...
Страница 136: ......
Страница 251: ...Section 7 Installation 251 FIGURE 46 Running Average Frequency Response FIGURE 47 Running Average Signal Attenuation ...
Страница 454: ...Section 8 Operation 454 FIGURE 104 Narrow Sweep High Noise ...
Страница 459: ...Section 8 Operation 459 FIGURE 106 Vibrating Wire Sensor Calibration Report ...
Страница 535: ...Section 8 Operation 535 8 11 2 Data Display FIGURE 121 CR1000KD Displaying Data ...
Страница 537: ...Section 8 Operation 537 FIGURE 123 CR1000KD Real Time Custom ...
Страница 538: ...Section 8 Operation 538 8 11 2 3 Final Storage Data FIGURE 124 CR1000KD Final Storage Data ...
Страница 539: ...Section 8 Operation 539 8 11 3 Run Stop Program FIGURE 125 CR1000KD Run Stop Program ...
Страница 541: ...Section 8 Operation 541 FIGURE 127 CR1000KD File Edit ...
Страница 542: ...Section 8 Operation 542 8 11 5 PCCard Memory Card Management FIGURE 128 CR1000KD PCCard Memory Card Management ...
Страница 546: ......
Страница 549: ...Section 9 Maintenance Details 549 FIGURE 133 Separate Back Shell from Module FIGURE 134 Disconnect Battery Connector ...
Страница 552: ......
Страница 610: ...Section 11 Glossary 610 FIGURE 137 Relationships of Accuracy Precision and Resolution ...
Страница 612: ......
Страница 648: ......
Страница 650: ......
Страница 688: ......
Страница 689: ......