Section 4. Sensor Installation
Sensor leads should be routed down the North side of the mast to the enclosure and
secured with cable ties.
4.1 034B Met One Windset
Mount the 034B to the CM202, CM204, or CM206 crossarm as shown in
Figure 4.1-1.
1.
Mount the CM220 bracket on the crossarm via the U-bolt and nuts.
2.
Place the 034B stem and bushing into the CM220 bracket.
3.
With the shoulder screw in place, orient the counter weight to point due
south. See Section 4.19 for final calibration.
4.
Tighten the CM220’s U-bolt and nuts and remove the shoulder screw.
FIGURE 4.1-1. Met One 034B Wind Speed and Direction Sensor