Section 2. CM6/CM10 Tripod Installation
FIGURE 2-6. Guy Wire Installation
1. Construct an assembly consisting of the top plate, wire ropes, 3 thimbles,
and 6 u-bolts.
a. Place a thimble into each of the three small holes of the top plate.
Twist each thimble slightly, as shown in Figure 2-7, to accomplish
this.
b. Thread a piece of wire rope through each of the three small top plate
holes. Double the wire rope back on itself about 8 inches. Clamp the
doubled wire with two u-bolts per wire, forming a loop. Fit the wire
loop into the thimble groove. Adjust the u-bolts as needed. Once the
thimble and wire loop are fitted together, tighten the u-bolts to secure
the clamps.
FIGURE 2-7. Thimble Twisting
2-8
Содержание CM10
Страница 12: ...Section 1 Preparation and Siting 1 6...
Страница 35: ...Section 3 Instrumentation Installation Datalogger Computer FIGURE 3 3 4 SRM 5A Wiring 3 11...
Страница 45: ...Section 4 Sensor Installation 107 Mounting Clamp FIGURE 4 5 1 107 Temperature Probe 4 5...
Страница 47: ...Section 4 Sensor Installation HMP50 Mounting Clamp FIGURE 4 7 1 HMP50 Temperature and RH Probe 4 7...
Страница 60: ...Section 4 Sensor Installation 4 20...
Страница 62: ...Section 5 Standard Software Installation 5 2...
Страница 67: ......