Safety 

DANGER — MANY HAZARDS ARE ASSOCIATED WITH INSTALLING, USING, MAINTAINING, AND WORKING ON OR AROUND 

TRIPODS, TOWERS, AND ANY ATTACHMENTS TO TRIPODS AND TOWERS SUCH AS SENSORS, CROSSARMS, ENCLOSURES, 

ANTENNAS, ETC

. FAILURE TO PROPERLY AND COMPLETELY ASSEMBLE, INSTALL, OPERATE, USE, AND MAINTAIN TRIPODS, 

TOWERS, AND ATTACHMENTS, AND FAILURE TO HEED WARNINGS, INCREASES THE RISK OF DEATH, ACCIDENT, SERIOUS 

INJURY, PROPERTY DAMAGE, AND PRODUCT FAILURE. TAKE ALL REASONABLE PRECAUTIONS TO AVOID THESE HAZARDS. 

CHECK WITH YOUR ORGANIZATION'S SAFETY COORDINATOR (OR POLICY) FOR PROCEDURES AND REQUIRED PROTECTIVE 

EQUIPMENT PRIOR TO PERFORMING ANY WORK. 

Use tripods, towers, and attachments to tripods and towers only for purposes for which they are designed. Do not exceed design limits. 

Be familiar and comply with all instructions provided in product manuals. Manuals are available at www.campbellsci.com or by 

telephoning (435) 227-9000 (USA). You are responsible for conformance with governing codes and regulations, including safety 

regulations, and the integrity and location of structures or land to which towers, tripods, and any attachments are attached. Installation 

sites should be evaluated and approved by a qualified engineer. If questions or concerns arise regarding installation, use, or 

maintenance of tripods, towers, attachments, or electrical connections, consult with a licensed and qualified engineer or electrician. 
General 

 

Prior to performing site or installation work, obtain required approvals and permits. Comply 

with all governing structure-height regulations, such as those of the FAA in the USA. 

 

Use only qualified personnel for installation, use, and maintenance of tripods and towers, and 

any attachments to tripods and towers. The use of licensed and qualified contractors is highly 

recommended. 

 

Read all applicable instructions carefully and understand procedures thoroughly before 

beginning work. 

 

Wear a

 hardhat 

and

 eye protection

, and take 

other appropriate safety precautions

 while 

working on or around tripods and towers.

 

 

Do not climb

 tripods or towers at any time, and prohibit climbing by other persons. Take 

reasonable precautions to secure tripod and tower sites from trespassers. 

 

Use only manufacturer recommended parts, materials, and tools. 

Utility and Electrical 

 

You can be killed

 or sustain serious bodily injury if the tripod, tower, or attachments you are 

installing, constructing, using, or maintaining, or a tool, stake, or anchor, come in 

contact with

 

overhead or underground utility lines

 

Maintain a distance of at least one-and-one-half times structure height, 20 feet, or the distance 

required by applicable law, 

whichever is greater

, between overhead utility lines and the 

structure (tripod, tower, attachments, or tools). 

 

Prior to performing site or installation work, inform all utility companies and have all 

underground utilities marked. 

 

Comply with all electrical codes. Electrical equipment and related grounding devices should be 

installed by a licensed and qualified electrician. 

Elevated Work and Weather 

 

Exercise extreme caution when performing elevated work. 

 

Use appropriate equipment and safety practices. 

 

During installation and maintenance, keep tower and tripod sites clear of un-trained or non-

essential personnel. Take precautions to prevent elevated tools and objects from dropping. 

 

Do not perform any work in inclement weather, including wind, rain, snow, lightning, etc. 

Maintenance 

 

Periodically (at least yearly) check for wear and damage, including corrosion, stress cracks, 

frayed cables, loose cable clamps, cable tightness, etc. and take necessary corrective actions. 

 

Periodically (at least yearly) check electrical ground connections. 

WHILE EVERY ATTEMPT IS MADE TO EMBODY THE HIGHEST DEGREE OF SAFETY IN ALL CAMPBELL SCIENTIFIC PRODUCTS, 

THE CUSTOMER ASSUMES ALL RISK FROM ANY INJURY RESULTING FROM IMPROPER INSTALLATION, USE, OR 

MAINTENANCE OF TRIPODS, TOWERS, OR ATTACHMENTS TO TRIPODS AND TOWERS SUCH AS SENSORS, CROSSARMS, 

ENCLOSURES, ANTENNAS, ETC. 

 

Содержание AM25T

Страница 1: ...AM25T Solid State Thermocouple Multiplexer Revision 1 19 Copyright 1995 2019 Campbell Scientific Inc...

Страница 2: ...ucts to CSI CSI will return such Products by surface carrier prepaid within the continental United States of America To all other locations CSI will return such Products best way CIP port of entry per...

Страница 3: ...ing address is CAMPBELL SCIENTIFIC INC RMA _____ 815 West 1800 North Logan Utah 84321 1784 For all returns the customer must fill out a Statement of Product Cleanliness and Decontamination form and co...

Страница 4: ...beginning work Wear a hardhat and eye protection and take other appropriate safety precautions while working on or around tripods and towers Do not climb tripods or towers at any time and prohibit cl...

Страница 5: ...nd G Ground Terminals 3 4 5 Analog Ground 3 4 6 Reset RES 3 4 7 Clock CLK 3 5 Terminal Strips 4 6 Specifications 5 7 Installation 6 7 1 Installing the AM25T 6 7 2 Data Logger to AM25T Wiring 7 7 3 Sen...

Страница 6: ...Terminal Strips 4 5 2 AM25T with Spring Loaded Terminals 5 7 1 External Battery Connections 7 7 2 Differential Measurement of Type T Thermocouple 9 7 3 Differential Voltage Measurement 9 8 1 Short Cu...

Страница 7: ...suitable for resistive bridge measurements high impedance of the solid state relays or multiplexing power 25 mA maximum switching current A maximum of 25 thermocouples differential voltage measurement...

Страница 8: ...ng material for product that may be concealed Check model number part numbers and product descriptions against the shipping documents Model or part numbers are found on each product On cables the numb...

Страница 9: ...rminal located between the VX and HI terminals Analog ground is not common with the other ground terminals labeled G The analog ground terminal must be connected to the data logger ground as shown in...

Страница 10: ...e length of the AM25T are for sensor connections All inputs are protected by spark gaps All terminals accept stripped and tinned wires up to AWG wire gauge 16 A strain relief flange is located between...

Страница 11: ...n tighten the screw 6 Specifications Power Unregulated 9 6 to 16 Vdc 12 Vdc nominal Current Drain Quiescent 0 5 mA Active 1 0 mA typical Enable Inactive 0 9 V Active 3 5 to 5 0 V 7 V max Clock The rel...

Страница 12: ...0 Maximum Switching Current 25 mA switching currents greater than 25 mA damages the relays and renders them unusable Compliance View the EU Declaration of Conformity at www campbellsci com am25t Assum...

Страница 13: ...te battery might be used when the AM25T is installed some distance from the data logger Ground must be connected between the data logger and the AM25T FIGURE 7 1 FIGURE 7 1 External Battery Connection...

Страница 14: ...rence PRT is located in the AM25T This reference temperature does not require an additional data logger input to measure the reference Thermal gradients between the AM25T sensor input terminals and th...

Страница 15: ...nsor Types Different sensors may be mixed on the AM25T Additional loops and measurement instructions will be required 8 Operation 8 1 General Measurement Considerations Wires have additional capacitan...

Страница 16: ...many program configurations for various supported sensors providing a quick way to generate a program and wiring diagram FIGURE 8 1 Short Cut can be downloaded free of charge www campbellsci com FIGU...

Страница 17: ...ntrol the AM25T multiplexer with the data logger The instruction measures the PRT incorporated in the AM25T and uses it as a reference temperature for thermocouple measurements The AM25T instruction a...

Страница 18: ...g the procedure in Section 4 Overview p 2 Finish the program On the Advanced tab click the CRBasic Editor button The program opens in CRBasic with the name noname CR_ Provide a name and save the progr...

Страница 19: ...Common High HI U5 Common Low LO U6 1 Analog Ground is the terminal located between the VX and HI terminals on the AM25T CRBasic Example B 1 CR6 Program Using One Instruction to Measure Both the Refere...

Страница 20: ...Battery BattV Default CR6 Datalogger Wiring Panel Temperature measurement PTemp_C PanelTemp PTemp_C 60 Type T copper constantan Thermocouple measurements Temp_C on the AM25T Multiplexer AM25T Temp_C 2...

Страница 21: ...Asia Location Bangkok Thailand Email info campbellsci asia Website www campbellsci asia China Location Beijing P R China Email info campbellsci com cn Website www campbellsci com cn Spain Location Ba...

Отзывы: