Campbell 092 Скачать руководство пользователя страница 24

Campbell Scientific Companies 

 

Campbell Scientific, Inc. (CSI) 

815 West 1800 North 

Logan, Utah  84321 

UNITED STATES 

www.campbellsci.com

 • in[email protected] 

 

Campbell Scientific Africa Pty. Ltd. (CSAf)

 

PO Box 2450 

Somerset West 7129 

SOUTH AFRICA 

www.csafrica.co.za

 • [email protected] 

 

Campbell Scientific Australia Pty. Ltd. (CSA)

 

PO Box 8108 

Garbutt Post Shop QLD 4814 

AUSTRALIA 

www.campbellsci.com.au

 • [email protected] 

 

Campbell Scientific do Brazil Ltda. (CSB)

 

Rua Luisa Crapsi Orsi, 15 Butantã 

CEP: 005543-000 São Paulo SP BRAZIL 

www.campbellsci.com.br

 • [email protected] 

 

Campbell Scientific Canada Corp. (CSC)

 

11564 - 149th Street NW 

Edmonton, Alberta T5M 1W7 

CANADA 

www.campbellsci.ca

 • [email protected] 

 

Campbell Scientific Centro Caribe S.A. (CSCC) 

300 N Cementerio, Edificio Breller 

Santo Domingo, Heredia 40305 

COSTA RICA 

www.campbellsci.cc

 • in[email protected] 

 

Campbell Scientific Ltd. (CSL)

 

Campbell Park 

80 Hathern Road 

Shepshed, Loughborough LE12 9GX 

UNITED KINGDOM 

www.campbellsci.co.uk

 • [email protected] 

 

Campbell Scientific Ltd. (France) 

3 Avenue de la Division Leclerc 

92160 ANTONY 

FRANCE 

www.campbellsci.fr

 • in[email protected] 

 

Campbell Scientific Spain, S. L. 

Avda. Pompeu Fabra 7-9, local 1 

08024 Barcelona 

SPAIN 

www.campbellsci.es

 • info@campbellsci.es 

 
 

Please visit www.campbellsci.com to obtain contact information for your local US or international representative. 

Содержание 092

Страница 1: ...Model 092 Barometric Pressure Sensor 6 12 C o p y r i g h t 2 0 1 2 C a m p b e l l S c i e n t i f i c I n c...

Страница 2: ......

Страница 3: ...emoving reinstalling and shipping defective products to Campbell Campbell will return such products by surface carrier prepaid within the continental United States of America To all other locations Ca...

Страница 4: ...g container Campbell Scientific s shipping address is CAMPBELL SCIENTIFIC INC RMA _____ 815 West 1800 North Logan Utah 84321 1784 For all returns the customer must fill out a Statement of Product Clea...

Страница 5: ...tements 1 3 Initial Inspection 1 4 Quickstart 1 4 1 Installation 1 4 2 Programming with Short Cut 3 5 Overview 6 6 Specifications 7 7 Installation 7 7 1 Mounting 7 7 2 Wiring 8 7 3 Programming 8 8 Mai...

Страница 6: ...able of Contents ii Tables 7 1 Connecting the 092 to Campbell Scientific Dataloggers 8 A 1 Dip Switches SW1 Analog Output Voltage Settings A 1 A 2 Dip Switches SW2 Analog Output Pressure Range Setting...

Страница 7: ...will not harm the sensor but the measurement accuracy is not guaranteed beyond the range of 600 to 1100 millibars 3 Initial Inspection Upon receipt of the 092 inspect the packaging and contents for d...

Страница 8: ...E 4 1 092 installed on a vertical mast Individual wire leads connect to the CR1000 datalogger as shown in step 5 of the procedure in Section 4 2 Programming with Short Cut A more generalized wiring di...

Страница 9: ...ogram Generator for Windows can be used to program the CR1000 datalogger to measure the 092 as outlined in the following procedure Short Cut can also program other 092 compatible Campbell Scientific d...

Страница 10: ...ressure Sensor and click the right arrow to add it to the list of sensors to be measured 4 Define the name of the public variable or use the default BP_mmHg to hold the barometric pressure measurement...

Страница 11: ...r are shown in the Wiring tab 6 Select the desired output data for final storage and click Finish 7 Click Wiring Diagram for a description of sensor wiring for this example Send the program from the P...

Страница 12: ...ined calibration coefficients The microcontroller polls the sensor module once per second Measurements are temperature corrected the calibration coefficients applied and the processed pressure measure...

Страница 13: ...g Term Stability 1 mbar in 12 months Temperature Operating range 40 to 55 C Compensated range 40 to 55 C Power requirement Source 6 16 Vdc Load 10 mA 12Vdc Output Analog 0 to 5 Vdc Enclosure Polycarbo...

Страница 14: ...example can be used in whole or in part if the datalogger is being programmed with CRBasic Editor Programming is similar with the CR800 and CR3000 CR1000 with 092 Barometric Pressure Sensor Wiring 1H...

Страница 15: ...cleaning of the sintered filter at the base of the unit may be required in dusty conditions Remove the filter and clean with distilled water 8 2 Calibration Calibration is performed against a NIST tra...

Страница 16: ...Model 092 Barometric Pressure Sensor 10...

Страница 17: ...sted in Tables A 1 and A 2 Highlighted settings are those set at the factory by Campbell Scientific Inc Complete information concerning measurement output and communications settings is available in t...

Страница 18: ...67 26 58 OFF ON OFF ON 700 1000 525 750 20 67 29 53 ON OFF OFF ON 700 1100 525 825 20 67 32 48 OFF OFF OFF ON 677 1 1083 6 508 0 812 8 20 00 32 00 ON ON ON OFF 800 900 600 675 23 62 26 58 OFF ON ON OF...

Страница 19: ...Appendix B Wiring The 092 ships from Campbell Scientific pre wired for analog output Internal cable connections are shown in Figure B 1 FIGURE B 1 Analog wiring B 1...

Страница 20: ...Appendix B Wiring B 2...

Страница 21: ...Appendix C CE Certification C 1...

Страница 22: ...Appendix C CE Certification C 2...

Страница 23: ......

Страница 24: ...ntific Canada Corp CSC 11564 149th Street NW Edmonton Alberta T5M 1W7 CANADA www campbellsci ca dataloggers campbellsci ca Campbell Scientific Centro Caribe S A CSCC 300 N Cementerio Edificio Breller...

Отзывы: