Model 092 Barometric Pressure Sensor
6. Specifications
Features
•
The following 092 barometer settings are configurable:
o
measurement range
o
data output option / communication option
o
analog output range
•
Specifications listed here are limited to those applicable to the 092 as
it is configured and shipped by Campbell Scientific, Inc.
Compatibility:
CR800
Series
CR1000
CR3000
CR23X
CR10(X)
Measurement
Range:
600 to 1100 mbar
Resolution:
0.1 mbar (.003 Hg)
Accuracy:
±0.35 mbar @ 25°C
±0.75 mbar @ 0 to55°C
±1.5 mbar @ -40°C
Long Term Stability:
±1 mbar in 12 months
Temperature
Operating range:
-40
to
55°C
Compensated range:
-40
to
55°C
Power requirement
Source:
6-16 Vdc
Load:
10 mA @ 12Vdc
Output:
Analog, 0 to 5 Vdc
Enclosure:
Polycarbonate
Size:
120 x 80 x 55 mm (4.7 x 3.1 x 2.2 in.)
CE Certification:
See Appendix C
Calibration:
Factory calibrated against a NIST
traceable anemometer.
7. Installation
7.1 Mounting
The 092 is factory mounted to a solar shield. The solar shield mounts by way
of two U-bolts to a vertical pipe with diameter up to 2” IPS. Install the sensor
such that it faces North in the Northern Hemisphere, or South in the Southern
Hemisphere. This orientation will shield the polycarbonate sensor housing
from most direct sunlight.
7