Operating Instructions

 

SN338K00

www.chpower.com

Operating Instructions 
(Continued)

RECOMMENDED HOOKUP

The illustration below shows the 
recommended hookup for the tool.

1.   The air compressor 

must be able to 
maintain a minimum 
of 60 psi when the 
tool is being used. An inadequate air 
supply can cause a loss of power and 
inconsistent driving.

2.   An oiler can be 

used to provide oil 
circulation through 
the tool. A filter can 
be used to remove 
liquid and solid impurities which can 
rust or “gum up” internal parts of 
the tool. 

3.   Always use air supply hoses with 

a minimum working pressure 
rating equal to or greater than the 
pressure from the power source if a 
regulator fails, or 150 psi, whichever 
is greater. Use 1/4 inch air hose for 
runs up to 50 feet. Use 3/8 inch or 
greater air hoses for 50 foot run or 
longer.

4.   Use a pressure regulator on the 

compressor, with an operating 
pressure of 0 - 125 psi. A pressure 
regulator is required to control 
the operating pressure of the tool 
between 60 and 100 psi. 

OPERATIONAL MODE - SINGLE CYCLE

 

Always know the  

  operational mode of 

the tool before using. Failure to know 
the operational mode could result in 
death or serious personal injury.

This tool requires the trigger to be 
pulled each time a nail is driven. The 
nailer can be actuated by depressing the 
WCE against the work surface followed 
by pulling the trigger. 

The trigger must be released to reset 
the tool before another nail can be 
driven.

WORK CONTACT ELEMENT (WCE)

 

Check the operation 

  of the Work Contact 

Element (WCE) trip mechanism before 
each use. The WCE must move freely 
without binding through its entire 
travel distance. The WCE spring must 
return the WCE to its fully extended 
position after being depressed. Do 
not operate the nailer if the WCE trip 
mechanism is not operating properly. 
Personal injury may occur.

1.   Disconnect the air 

supply from the tool.

2.   Remove all fasteners 

from the magazine 
(see Loading/ 
Unloading).

3.   Make sure the trigger 

and work contact 
element (WCE) move 
freely up and down 
without sticking or 
binding.

4.   Reconnect air supply 

to the tool.

5.   Depress the Work 

Contact Element 
(WCE) against the 
work surface without 
pulling the trigger. 
The tool 

MUST NOT OPERATE

Do not use the tool if it operates 
without pulling the trigger. Personal 
injury may result.

6.   Remove the tool from 

the work surface. 
The Work Contact 
Element (WCE) must 
return to its original 
down position. The tool 

MUST NOT 

OPERATE

. Do not use the tool if it 

operates while lifted from the work 
surface. Personal injury may result.

7.   Pull the 

trigger 
and 
depress 
the work 
contact 
element (WCE) against the work 
surface. The tool 

MUST NOT 

OPERATE

.

8.   Depress 

the Work 
Contact 
Element 
(WCE) 
against 
the work surface. Pull the trigger. 
The tool 

MUST OPERATE

.

 An 

improperly 

 functioning 

tool 

must not be used. Do not actuate the 
tool unless the tool is placed fi rmly 
against the work piece.

150 psi or greater

60 psi 
Min.

100 psi 
Max.

Minimum Recommended Hookup

Quick Plug

Quick 
Coupler

Air Hose

Quick Plug

Quick 

Coupler

Содержание IN729300AV

Страница 1: ...unpacking the unit inspect carefully for any damage that may have occurred during transit Make sure to tighten fittings bolts etc before putting unit into service Model SN338K00 Safety Guidelines Thi...

Страница 2: ...K AREA a Keep the work area clean and well lighted Cluttered benches and dark areas increase the risks of electric shock fire and injury to persons b Do not operate the tool in explosive atmospheres s...

Страница 3: ...tool to the air supply with the switch on d Do not overreach Keep proper footing and balance at all times Proper footing and balance enables better control of the tool in unexpected situations e Use...

Страница 4: ...n from the pusher before attempting to clear jams because fasteners can be ejected from the front of the tool Personal injury may occur AIR SOURCE a Never connect to an air source that is capable of e...

Страница 5: ...the tool before another nail can be driven WORK CONTACT ELEMENT WCE Check the operation of the Work Contact Element WCE trip mechanism before each use The WCE must move freely without binding through...

Страница 6: ...sconnect the air supply from the tool 2 Remove all fasteners from the magazine see Loading Unloading Failure to do so will cause the nails to eject from the front of the tool 3 Loosen cap screws on no...

Страница 7: ...100 5000 FN180615 1 2 inch 18 Gauge 1 4 inch Chisel Galvanized Vinyl Coated Adhesive 100 1000 FN180620 3 4 inch 18 Gauge 1 4 inch Chisel Galvanized Vinyl Coated Adhesive 100 1000 FN180625 1 inch 18 G...

Страница 8: ...r damage prevent fasteners or pusher from moving freely in magazine 3 Clean magazine 4 Damaged pusher spring 4 Replace spring 5 Inadequate air flow to tool 5 Check fitting hose or compressor 6 Worn O...

Страница 9: ...9 Operating Instructions SN338K00 www chpower com Date Maintenance Performed Repair Components Required Service Record...

Страница 10: ...glect or failure to operate products in accordance with instructions shall also include the removal or alteration of any safety devices If such safety devices are removed or altered this warranty is v...

Страница 11: ...surer de resserrer tous les raccords boulons etc avant de le mettre en service Directives de S curit Ce manuel contient de l information tr s importante qui est fournie pour la S CURIT et pour VITER L...

Страница 12: ...et bien clair e Les tablis encombr s et les coins sombres augmentent les risques de chocs lectriques d incendie et de blessures aux personnes b Ne pas faire fonctionner l outil dans une atmosph re exp...

Страница 13: ...imentation d air Ne pas transporter l outil avec le doigt sur l interrupteur ni brancher l outil l alimentation d air avec l interrupteur en marche d Ne pas trop se pencher Garder bon pied et bon quil...

Страница 14: ...il sans d abord obtenir une approbation crite de Campbell Hausfeld N utilisez pas d outil si les crans ou protecteurs ont t enlev s ou alt r s Ne pas utiliser l outil comme marteau Cela peut entra ner...

Страница 15: ...SME DE D CLENCHEMENT PAR CONTACT WCE V rifier le fonctionnement du m canisme de d clenchement par contact WCE avant chaque usage Le WCE doit fonctionner avec un mouvement libre sans restrictions Le re...

Страница 16: ...r caution n est pas prise l jection accidentelle de clous peut se produire lorsque l on d monte le nez de l appareil 3 Oter les 3 vis t te cylindrique du nez de l appareil et d poser la plaque de garn...

Страница 17: ...180615 12 7 mm 1 2 po 18 1 4 po Burin Galvanis Enduit de Vinyle Adh sive 100 1000 FN180620 19 1 mm 3 4 po 18 1 4 po Burin Galvanis Enduit de Vinyle Adh sive 100 1000 FN180625 2 54 cm 1 po 18 1 4 po Bu...

Страница 18: ...oussoir dans le chargeur 3 Nettoyer le chargeur 4 Ressort de poussoir endommag 4 Remplacer le ressort 5 Circulation d air insuffisante la cloueuse 5 Inspecter le raccord tuyau ou le compresseur 6 Join...

Страница 19: ...19 Fr Instructions d Utilisation SN338K00 Date Entretien Ex cut l ments de Remplacement Requis Enregistrement d Entretien...

Страница 20: ...onctionner les produits selon les instructions comprend aussi l enlevage ou la modification de n importe quel appareil de s ret Si ces appareils de s ret sont enlev s ou modifi s la garantie sera annu...

Страница 21: ...erciorarse de que est en perfecto estado Cerici rese de apretar todas las conexiones pernos etc antes de comenzar a utilizar la unidad Medidas de Seguridad Este manual contiene informaci n que es muy...

Страница 22: ...la MUERTE o en LESIONES GRAVES REA DE TRABAJO a Mantenga el rea de trabajo limpia y bien iluminada Los bancos desordenados y las reas oscuras aumentan el riesgo de choque el ctrico incendio y lesione...

Страница 23: ...a manera pr ctica de asegurar y apoyar la pieza de trabajo a una plataforma estable Sostener el trabajo con la mano o contra el cuerpo es algo inestable y puede producir la p rdida de control b No fue...

Страница 24: ...a El servicio de la herramienta debe ser realizado s lo por personal de reparaciones calificado b Al realizarle un servicio a la herramienta utilice nicamente piezas de repuesto id nticas Use s lo pie...

Страница 25: ...resi n de operaci n de la herramienta entre 4 83 bar y 7 58 bar MODEO DE OPERACI N CICLO SENCILLO Siempre cerci rese de saber en qu modo va a operar la herramienta antes de comenzar a usarla De lo con...

Страница 26: ...de trabajo 1 Ajuste la presi n de operaci n a aqu lla que usar con regularidad para clavar los clavos No exceda la presi n de operaci n m xima de 6 90 bar 2 Para dirigir el calador de clavos gire la...

Страница 27: ...en usar con las grapadoras Senco LN4450 SJS LR SKS L11 15 Hitachi N3804A Duofast BN 1832S KN 1848 ST 18 Stan Tech SDS 18 14 Atro Minor 90 30 90 32 90 40 y Porter Cable NS100 SUJETADOR Y PIEZAS DE REPU...

Страница 28: ...el mecanismo de impulso est da ado 4 Debe reemplazar el resorte 5 El flujo de aire hacia la herramienta es inadecuado 5 Chequ e las conexiones la manguera o el compresor 6 El anillo en O del pist n es...

Страница 29: ...29 Sp Manual de Instrucciones de Operaci n SN338K00 Fecha Maintenimiento Efectuado Componentes de Reparaci n Necesarios Registro de Servicios...

Страница 30: ...ir la desconexi n o modificaci n de los instrumentos de seguridad Si dichos instrumentos de seguridad son desconectados la garant a quedar a cancelada D Los ajustes normales explicados en el los manua...

Страница 31: ...31 Operating Instructions Instructions d Utilisation Manual de Instrucciones de Operaci n SN338K00 Notes Notes Notas...

Страница 32: ...32 Operating Instructions Instructions d Utilisation Manual de Instrucciones de Operaci n SN338K00 Notes Notes Notas...

Отзывы:

Похожие инструкции для IN729300AV