manualshive.com logo in svg
background image

2

Operating Instructions and Parts Manual

www.chpower.com

General Safety Information

CaLIFOrnIa PrOPOSItIOn 65

 

This product or its 

  power cord may 

contain chemicals, including lead, 
known to the State of California to 
cause cancer and birth defects or other 
reproductive harm. Wash hands after 
handling.
 

You can  

  create 

dust when you cut, sand, drill 
or grind materials such as 
wood, paint, metal, concrete, 
cement, or other masonry. This dust 
often contains chemicals known to 
cause cancer, birth defects, or other 
reproductive harm. Wear protective 
gear.

GeneraL SaFety

Since the air compressor and other 
components (material pump, spray 
guns, filters, lubricators, hoses, etc.) 
used, make up a high pressure pumping 
system, the following safety precautions 
must be observed at all times:

 

Do not run  

  unattended. Leaving 

compressor in AUTO position may allow 
it to turn on inadvertently. To prevent 
this and possible damage from power 
surge, turn to OFF position after each 
use. 

1.  Read all manuals included 

with this product carefully. 
Be thoroughly familiar 
with the controls and the 
proper use of the equipment.

 2.  Follow all local electrical and safety 

codes as well as in the United States, 
the National Electrical Codes (NEC) 
and Occupational Safety and Health 
Act (OSHA).

 3.  Only persons well acquainted with 

these rules of safe operation should 
be allowed to use the compressor.

4.  Keep visitors away and NEVER allow 

children in the work area.

5.  Wear safety glasses and 

use hearing protection 
when operating the unit.

6.  Do not stand on or use the unit as a 

handhold.

7.  Before each use, inspect compressed 

air system and electrical components 
for signs of damage, deterioration, 
weakness or leakage. Repair or 
replace defective items before using.

8.  Check all fasteners at frequent 

intervals for proper tightness.

 

Motors,  

  electrical 

equipment and controls can 
cause electrical arcs that 
will ignite a flammable gas 
or vapor. Never operate or repair in or 
near a flammable gas or vapor. Never 
store flammable liquids or gases in the 
vicinity of the compressor.
  

 

Compressor parts may be hot 
even if the unit is stopped.

9.  Keep fingers away from a  

running compressor; fast moving 
and hot parts will cause injury and/
or burns.

10. If the equipment should start to 

vibrate abnormally, STOP the engine/
motor and check immediately for 
the cause. Vibration is generally a 
warning of trouble.

11. To reduce fire hazard, 

keep engine/motor 
exterior free of oil, 
solvent, or excessive 
grease.

 

Never remove or 

 

attempt to adjust 

safety valve. Keep safety valve free 
from paint and other accumulations.
 

Never use plastic 

  (PVC) pipe for 

compressed air. Serious injury or death 
could result.
 

Never  

  attempt 

to repair or modify a tank! 
Welding, drilling or any other 
modification will weaken the 
tank resulting in damage from rupture 
or explosion. Always replace worn, 
cracked or damaged tanks.
 

Drain liquid from  

  tank daily.

12. Tanks rust from moisture build-up, 

which weakens the tank. Make sure 
to drain tank regularly and inspect 
periodically for unsafe conditions 
such as rust formation and corrosion.

13. Fast moving air will stir up dust 

and debris which may be harmful. 
Release air slowly when draining 
moisture or depressurizing the 
compressor system.

SPrayInG PreCaUtIOnS

 

Do not  

 

spray 

flammable materials in 
vicinity of open flame or near 
ignition sources including the 
compressor unit.

14. Do not smoke when spraying paint, 

insecticides, or other flammable 
substances.

15. Use a face mask / 

respirator when spraying 
and spray in a well 
ventilated area to prevent 
health and fire hazards.

16. Do not direct paint or other sprayed 

material at the compressor. Locate 
compressor as far away from the 
spraying area as possible to minimize 
overspray accumulation on the 
compressor.

17. When spraying or cleaning with 

solvents or toxic chemicals, follow 
the instructions provided by the 
chemical manufacturer.

MANUAL

Содержание HL540200

Страница 1: ...ctions Do Not Discard Caution indicates a potentially hazardous situation which if not avoided MAY result in minor or moderate injury Notice indicates important information that if not followed may ca...

Страница 2: ...trols can cause electrical arcs that will ignite a flammable gas or vapor Never operate or repair in or near a flammable gas or vapor Never store flammable liquids or gases in the vicinity of the comp...

Страница 3: ...amination This debris will damage the motor Electrical Installation All wiring and electrical connections should be performed by a qualified electrician Installation must be in accordance with local c...

Страница 4: ...build to maximum pressure and shut off 5 With hose attached to outlet of compressor attach tire chuck or other tool to open end of hose 6 Adjust regulator to proper pressure for tool or tire Operate t...

Страница 5: ...spect 3 If the filter element is dirty or clogged replace it 4 Reinstall filter and cover Important Locate unit as far from spraying area as hose will allow to prevent overspray from clogging filter E...

Страница 6: ...sor shuts off 1 Loose connections fittings tubing etc 1 Check all connections with soap and water solution Tighten or remove and apply pipe dope or pipe tape to the threads then reassemble 2 Open tank...

Страница 7: ...r 2 Clean or replace filter 3 Circuit overloaded 3 Check for proper fuse use time delay fuse Disconnect other electrical appliances from circuit or operate compressor on its own branch circuit 4 Exten...

Страница 8: ...8 Operating Instructions and Parts Manual www chpower com 1 2 3 29 28 27 25 26 4 24 23 5 7 8 9 11 12 13 10 14 15 14 17 9 8 16 22 5 21 19 20 18 6 Figure 7 Repair parts illustration for model HL540200...

Страница 9: ...t n 2 10 Exhaust tube n 1 11 Drain valve HL030700AV 1 12 Tank assembly 1 13 Bolt M6 x 12 k 2 14 Washer M6 l 6 15 Bolt M6 x 16 l 4 16 Base 1 17 Foot l 4 18 Plug 1 19 Pressure regulator HL030800AV 1 20...

Страница 10: ...Manual www chpower com Figure 8 Repair parts illustration for HL360000AV pump motor 26 1 46 8 9 2 5 47 1 3 4 5 6 7 10 11 22 18 19 12 16 15 13 14 20 17 15 21 22 30 23 24 29 25 28 27 18 31 32 34 35 33...

Страница 11: ...f Part No Description No Qty 36 Bearing 1 37 Rotor 1 38 Bearing 1 39 Stator with thermal protector 1 40 Rear end bell 1 41 Fan t 1 42 Snap ring t 1 43 Plain washer M5 k 4 44 Lock washer M5 k 4 45 Moto...

Страница 12: ...lve failure caused by rain excessive humidity corrosive environments or other contaminants c Cosmetic defects that do not interfere with compressor functionality d Rusted tanks including but not limit...

Страница 13: ...S CONSERVER CES INSTRUCTIONS Ne pas jeter Directives de S curit Ce manuel contient de l information tr s importante qui est fournie pour la S CURIT et pour VITER LES PROBL MES D QUIPEMENT Rechercher l...

Страница 14: ...mmandes lectriques peuvent causer des arcs lectriques qui peuvent allumer un gaz ou une vapeur inflammable Ne jamais utiliser ou r parer le mod le pr s d un gaz ou d une vapeur inflammable Ne jamais e...

Страница 15: ...es objets Ne pas situer la prise d air du compresseur pr s de la vapeur un jet pulv ris de peinture endroits de d capage au sable ou autre sources de contamination Le d bris endommagera le moteur Inst...

Страница 16: ...sens antihoraire pour fermer le d bit d air 3 Tourner l interrupteur la position AUTO automatique 4 Le compresseur accumulera la pression jusqu ce qu il atteint la pression maximum et s arr tera 5 Av...

Страница 17: ...5 Changer l huile apr s chaque 50 heures d usage ENTRETIEN DU FILTRE D AIR D ASPIRATION Retrait inspection et remplacement Figure 6 Il faut retirer l l ment du filtre d aspiration et le v rifier r gu...

Страница 18: ...non retour avec de l air dans le r servoir purger le r servoir 4 Soupape de d charge d fectueuse sur le manostat 4 Remplacer la soupape de d charge 5 Condensateur s de moteur d fectueux 5 Remplacer l...

Страница 19: ...iltre d air obstru 2 Nettoyer ou remplacer 3 Surcharge de circuit 3 V rifier le type de fusible utiliser un fusible retardement D brancher les autres appareils lectriques du circuit ou faire fonctionn...

Страница 20: ...r Instructions d Utilisation et Manual de Pi ces 1 2 3 29 28 27 25 26 4 24 23 5 7 8 9 11 12 13 10 14 15 14 17 9 8 16 22 5 21 19 20 18 6 Figure 7 Illustration des pi ces de r paration pour mod le HL540...

Страница 21: ...030700AV 1 12 Assemblage du r servoir 1 13 Boulon M6 x 12 k 2 14 Rondelle M6 l 6 15 Boulon M6 x 16 l 4 16 Base 1 17 Pied l 4 18 Bouchon 1 19 R gulateur de pression HL030800AV 1 20 Mamelon simple bicon...

Страница 22: ...l de Pi ces 26 1 46 8 9 2 5 47 1 3 4 5 6 7 10 11 22 18 19 12 16 15 13 14 20 17 15 21 22 30 23 24 29 25 28 27 18 31 32 34 35 33 36 37 38 39 44 34 33 40 41 45 42 43 Figure 8 Illustration des pi ces de r...

Страница 23: ...ription No Qty 36 Palier 1 37 Rotor 1 38 Palier 1 39 Stator avec protecteur de surcharge thermique 1 40 Ch ssis arri re du moteur 1 41 Ventilateur t 1 42 Bague d arr t t 1 43 Rondelle plate M5 k 4 44...

Страница 24: ...me qui n ont pas d effet sur le fonctionnement du compresseur d Les r servoirs rouill s y compris mais sans s y limiter la rouille caus e par la vidange incorrecte ou par un environnement corrosif e L...

Страница 25: ...GA TODAS LAS INSTRUCCIONES GUARDE ESTAS INSTRUCCIONES NO LAS DESECHE Medidas de Seguridad Este manual contiene informaci n que es muy importante que sepa y comprenda Esta informaci n se la suministram...

Страница 26: ...pare el compresor cerca de gases o vapores inflamables Nunca almacene l quidos o gases inflamables cerca del compresor Las piezas del compresor podr an estar calientes inclusive cuando la unidad est a...

Страница 27: ...el motor Instalaci n el ctrica Todas las conexiones el ctricas y el alambrano deber n ser llevados a cabo por un electricista profesional La instalaci n debe estar conforme con los c digos locales y...

Страница 28: ...onamiento 1 Coloque el interruptor en OFF y conecte el cord n al tomacorrientes 2 Gire la perilla del regulador en sentido antihorario para cerrar el flujo de aire 3 Coloque el interruptor en Auto 4 E...

Страница 29: ...ruido c mbielo 4 Vuelva a instalar el filtro y la cubierta ImportantE Para prevenir que el exceso de pulverizaci n atore el filtro coloque la unidad tan lejos del rea de pulverizaci n como le permita...

Страница 30: ...tanque baja cuando el compresor se apaga 1 Conexiones flojas conexiones tuber as etc 1 Revise todas las conexiones con una soluci n de agua y jab n Apriete o retire y aplique sellador o cintas para r...

Страница 31: ...e de que est usando el fusible adecuado use un fusible de acci n retardada Desconecte los otros artefactos el ctricos del circuito o conecte el compresor a otro circuito 4 Uso del cable de extensi n c...

Страница 32: ...anual de Instrucciones y Lista de Piezas 32 Sp 1 2 3 29 28 27 25 26 4 24 23 5 7 8 9 11 12 13 10 14 15 14 17 9 8 16 22 5 21 19 20 18 6 Figura 7 Ilustraci n de las piezas de repuesto para modelo HL54020...

Страница 33: ...n 1 11 V lvula de drenaje HL030700AV 1 12 Ensamble del tanque 1 13 Perno M6 x 12 k 2 14 Arandela M6 l 6 15 Perno M6 x 16 l 4 16 Base 1 17 Pata l 4 18 Tap n 1 19 Regulador de presi n HL030800AV 1 20 Ni...

Страница 34: ...as 34 Sp 26 1 46 8 9 2 5 47 1 3 4 5 6 7 10 11 22 18 19 12 16 15 13 14 20 17 15 21 22 30 23 24 29 25 28 27 18 31 32 34 35 33 36 37 38 39 44 34 33 40 41 45 42 43 Figura 8 Ilustraci n de las piezas de re...

Страница 35: ...on No Qty 36 Cojinete 1 37 Rotor 1 38 Cojinete 1 39 Estator con protector de sobrecarga t rmica 1 40 Marco en campana del extremo posterior del motor 1 41 Ventilador t 1 42 Anillo a presi n t 1 43 Ara...

Страница 36: ...ten el funcionamiento del compresor d Tanques oxidados incluyendo pero no limitado al xido debido al drenaje inadecuado u agentes corrosivos en el ambiente e Las siguientes piezas se consideran art cu...

Отзывы: