Air Compressors

Maintenance

Release all 
pressure and

disconnect power before making any
repair.

1. Check compressor for any visible

problems.

2. Pull ring on safety valve and allow it to

snap back to normal position.

Safety valve must 
be replaced if it

cannot be actuated or it leaks air after ring
is released.

3. With compressor shut off reduce tank

pressure below 10 psi, then drain
moisture from tank daily to avoid tank
corrosion. The procedure to drain tank
depends on the compressor type:

For pancake units: 

Drain by tilting

tank.

For horizontal units:

No tilting is

necessary to drain.

!

WARNING

!

WARNING

4. Turn power OFF and clean dust and dirt

from motor, tank, air lines and pump
cooling fins.

NOTE: 

This unit has no air filter to

maintain.

IMPORTANT: 

Unit should be located as

far from spraying area as hose will allow.

LUBRICATION

This is a compressor that requires no
additional lubrication.

THERMAL OVERLOAD PROTECTOR

This compressor is 
equipped with an

automatic reset thermal overload
protector which will shut off motor if it
becomes overheated.

!

CAUTION

If thermal overload protector shuts motor
OFF frequently look for the following
causes.

1. Low voltage.

2. Wrong gauge wire or length of

extension cord.

3. Lack of proper ventilation.

The motor must be 
allowed to cool

down before start-up is possible. The
motor will automatically restart without
warning if left plugged into electrical
outlet, if the motor is turned on.

STORAGE

1. When not in use, hose and compressor

should be stored in a cool dry place.

2. Tank should be drained of moisture.

3. Hose should be disconnected and hung

open ends down to allow any moisture
to drain.

!

CAUTION

Drain
Cock

Figure 8

Figure 7

www.chpower.com

Troubleshooting Chart

Symptom

Possible Cause(s)

Corrective Action

1. Loss of power or overheating

2. No electrical power
3. Breaker open/blown fuse
4. Thermal overload open
5. Pressure switch bad
6. Tank is full of air

1. Low voltage
2. Wrong gauge wire or length of

extension cord

3. Shorted or open motor winding

4. Defective check valve or unloader

1. Check for proper use of extension cord (see

EXTENSION CORDS, page 3)

2. Plugged in? Check fuse/breaker or motor overload

3. Reset breaker or replace blown fuse.
4. Motor will restart when cool
5. Replace
6. Compressor will turn on when tank pressure drops to

cut in pressure

1. Check with voltmeter
2. Check gauge chart, under Operation for proper

gauge wire and cord length

3. Take compressor to authorized Campbell Hausfeld

service center

4. Take compressor to authorized Campbell Hausfeld

service center

Compressor will not run

Motor hums but cannot
run or runs slowly

Problema

Posible(s) Causa(s)

Acción a Tomar  

1. Pérdida de potencia o se

sobrecalienta

2. No hay energía eléctrica

3. Disyuntor abierto/fusible quemado

4. Protector térmico desconectado

5. Presostato dañado

6. El tanque está lleno de aire

1. Voltaje bajo

2. Cordón de extensión inadecuado

3. Defecto de la bobina del motor

4. Válvula de chequeo o desfogue

defectuosa

1. Fusible inadecuado, circuito

sobreacrgado

2. Cordón de extensión inadecuado

3. Válvula de chequeo o desfogue

defectuosa

1. Voltaje bajo

2. Poca ventilación/temperatura

ambiental muy alta

3. Cordón de extensión inadecuado

1. Chequee el cordón de extensión adecuado (vea la

sección CORDONES DE EXTENSION, página 3)

2. ¿Está conectado? Chequee el fusible/cortacircuito o

protector de sobrecarga del motorfuse/breaker or
motor overload

3. Reposicione el disyuntor o reemplace el fusible

quemado

4. Espere a que el motor se enfrie

5. Reemplácelo

6. El compresor se encenderá cuando la presión del

tanque disminuya a la presión de arranque

1. Chequee con un voltimetro

2. Chequee la tabla sobre los calibres y longitudes

adecuadas del cordón

3. Lleve el compresor a un centro de servicio Campbell

Hausfeld autorizado

4. Lleve el compresor a un centro de servicio Campbell

Hausfeld autorizado

1. Cerciórese de que está usando el fusible adecuado.

Desconecte los otros artefactos del circuito o conecte
el compresor a otro circuito

2. Chequee la tabla en la sección de funcionamiento

3. Lleve el compresor a un centro de servicio Campbell

Hausfeld autorizado

1. Chequée con un voltimetro

2. Mueva el compresor a un área bien ventilada

3. Chequée la tabla en la sección de funcionamiento

Compresor no funciona

Motor hace ruido pero
no funciona o funciona
lentamente

Fusibles/cortacircuito se
activa con frecuencia 

El protector de
sobrecarga térmica se
activa constantemente

Guía de Diagnóstico de Averías