background image

6

Operating Instructions

www.chpower.com

Symptom

Possible Cause(s)

Corrective Action

Air leaking at trigger valve 
area.

O-Rings in trigger valve housing are 
damaged

Replace o-rings 

Air leaking between housing 
and nose.

1. Damaged O-Rings

1. Replace o-rings

2. Damage to bumper

2. Replace bumper

 Air leaking between housing 
and cap.

1. Loose screws

1. Tighten screws

2. Damaged gasket

2. Replace gasket

Tool skips driving fastener

1.  Worn bumper

1.  Replace bumper

2.  Dirt in nose piece

2.  Clean drive channel

3.  Dirt or damage prevent fasteners or 

pusher from moving freely in magazine

3. Clean magazine

4. Damaged pusher spring

4. Replace spring

5.  Inadequate air flow to tool

5.  Check fitting, hose, or compressor

6.  Worn O-Ring on piston or lack of 

lubrication

6.  Replace and lubricate o-rings

7.  Damaged O-Ring on trigger valve

7.  Replace o-rings

8.  Air leaks

8.  Tighten screws and fittings

9. Cap gasket leaking

9. Replace gasket

Tool runs slow or has loss of 
power

 1.  Tool not lubricated sufficiently

1.   Lubricate tool

2.  Broken spring in cylinder cap

2.  Replace spring

3.  Exhaust port in cap is blocked

3.  Replace damaged internal parts

Fasteners are jammed in tool

1.  Guide on driver is worn

1.  Replace guide

2.  Fasteners are not correct size

2.  Use only recommended fasteners

3.  Fasteners are bent

3.  Replace with undamaged fasteners

4.  Magazine or nose screws are loose

4.  Tighten screws

5. Driver is damaged

5. Replace driver

Troubleshooting Chart

  

Stop using tool immediately if any of the following problems occur. Serious personal injury could occur.  

  Any repairs or replacements must be done by a Qualifi ed Service Person or Authorized Service Center.

Содержание CHN10600

Страница 1: ...icates an imminently hazardous situation which if not avoided WILL result in death or serious injury Warning indicates a potentially hazardous situation which if not avoided COULD result in death or s...

Страница 2: ...Avoid unintentional starting Be sure the switch is off before connecting to the air supply Do not carry the tool with your finger on the switch or connect the tool to th air supply with the switch on...

Страница 3: ...ts changing accessories or storing the tool Such preventive safety measures reduce the risk of starting the tool unintentionally e Store the tool when it is idle out of reach of children and other unt...

Страница 4: ...it the air pressure supplied to the tool The regulated pressure must not exceed 100 psi If the regulator fails the pressure delivered to the tool must not exceed 200 psi The tool could explode which w...

Страница 5: ...moving tool from service Unloading is the reverse of loading except always disconnect the air hose before unloading ADJUSTING THE DIRECTION OF THE EXHAUST The tool is equipped with an adjustable direc...

Страница 6: ...n piston or lack of lubrication 6 Replace and lubricate o rings 7 Damaged O Ring on trigger valve 7 Replace o rings 8 Air leaks 8 Tighten screws and fittings 9 Cap gasket leaking 9 Replace gasket Tool...

Страница 7: ...7 CHN10600 www chpower com Notes...

Страница 8: ...use neglect or failure to operate products in accordance with instructions shall also include the removal or alteration of any safety devices If such safety devices are removed or altered this warrant...

Страница 9: ...er indique une situation hasardeuse imminente qui R SULTERA en perte de vie ou blessures graves Avertissement indique une situation hasardeuse potentielle qui PEUT r sulter en perte de vie ou blessure...

Страница 10: ...el S assurer que l interrupteur est en position d arr t off avant de brancher l alimentation d air Ne pas transporter l outil avec le doigt sur l interrupteur ni brancher l outil l alimentation d air...

Страница 11: ...raves blessures Ne toucher la g chette qu au moment de poser des attaches Ne jamais actionner la g chette durant le transport de l outil ou durant le raccordement de celle ci au tuyau d air comprim L...

Страница 12: ...e qui pourrait provoquer des blessures graves voire la mort Utiliser seulement une source d air comprim pression pour limiter la pression d air fournie l outil La pression contr l e ne doit pas d pass...

Страница 13: ...lenche 5 Toujours retirer tous les agrafes du chargeur avant de ranger la agrafeuse L op ration de d chargement s effectue l inverse de l op ration de chargement mais il faut toujours d brancher le tu...

Страница 14: ...ou manque de lubrification 6 Remplacer les joints torique 7 Joint torique de la soupape de g chette endommag 7 Remplacer les joints torique 8 Fuites d air 8 Serrer les vis et raccords 9 Fuite du join...

Страница 15: ...15 Fr CHN10600 Notes...

Страница 16: ...on abusive par l acheteur la n gligence ou le manque de faire fonctionner les produits selon les instructions comprend aussi l enlevage ou la modification de n importe quel appareil de s ret Si ces ap...

Страница 17: ...sto le indica que hay una situaci n inmediata que LE OCASIONARIA la muerte o heridas de gravedad sto le indica que hay una situaci n que PODRIA ocasionarle la muerte o heridas de gravedad sto le indi...

Страница 18: ...tornos explosivos como por ejemplo cuando haya polvo l quidos o gases inflamables La herramienta puede crear chispas y provocar la ignici n de polvo o vapores c Mantenga alejados a los observadores ni...

Страница 19: ...personales No toque el gatillo a menos que se est n clavando sujetadores Nunca haga arrancar la l nea de aire con una herramienta ni mueva la herramienta cuando est tocando el gatillo La herramienta p...

Страница 20: ...uerte o graves lesiones personales Use solamente una fuente de aire comprimido de presi n regulada para limitar la presi n de aire suministrada a la herramienta La presi n regulada no debe exceder los...

Страница 21: ...mienta de servicio La descarga se hace siguiendo el proceso inverso de la carga sin embargo siempre se tiene que desconectar la manguera de aire antes de descargarla PARA AJUSTAR LA DIRECCION DEL TUBO...

Страница 22: ...Manual de Instrucciones de Operaci n 22 Sp Notas...

Страница 23: ...los anillos en O Lubr quelos 7 Los anillos en O de la v lvula del gatillo est n da ados 7 Debe reemplazar los anillos en O 8 Hay fugas de aire 8 Debe apretar los tornillos y las conexiones 9 Hay una...

Страница 24: ...manual de instrucciones suministrado tambi n debe incluir la desconexi n o modificaci n de los instrumentos de seguridad Si dichos instrumentos de seguridad son desconectados la garant a quedar a canc...

Отзывы:

Похожие инструкции для CHN10600