77/89 Device handbook A
PLUS
with / without LED display
,
157
679-19, 04/2016
No.
Name
Description
Name (Display)
317
P2IN_HT
Meter P2 incoming high tariff
P2I.H
318
P3IN_HT
Meter P3 incoming high tariff
P3I.H
319
Q1IN_HT
Meter Q1 incoming high tariff
Q1I.H
320
Q2IN_HT
Meter Q2 incoming high tariff
Q2I.H
321
Q3IN_HT
Meter Q3 incoming high tariff
Q3I.H
322
P1IN_LT
Meter P1 incoming low tariff
P1I.L
323
P2IN_LT
Meter P2 incoming low tariff
P2I.L
324
P3IN_LT
Meter P3 incoming low tariff
P3I.L
325
Q1IN_LT
Meter Q1 incoming low tariff
Q1I.L
326
Q2IN_LT
Meter Q2 incoming low tariff
Q2I.L
327
Q3IN_LT
Meter Q3 incoming low tariff
Q3I.L
328
CNTR_IO2_HT
Meter I/O 2 high tariff
E 2.H
329
CNTR_IO6_HT
Meter I/O 6 high tariff
E 6.H
330
CNTR_IO7_HT
Meter I/O 7 high tariff
E 7.H
331
CNTR_IO8_HT
Meter I/O 8 high tariff
E 8.H
332
CNTR_IO9_HT
Meter I/O 9 high tariff
E 9.H
333
CNTR_IO10_HT
Meter I/O 10 high tariff
E10.H
334
CNTR_IO11_HT
Meter I/O 11 high tariff
E11.H
335
CNTR_IO2_LT
Meter I/O 2 low tariff
E 2.L
336
CNTR_IO6_LT
Meter I/O 6 low tariff
E 6.L
337
CNTR_IO7_LT
Meter I/O 7 low tariff
E 7.L
352
CNTR_IO8_LT
Meter I/O 8 low tariff
E 8.L
353
CNTR_IO9_LT
Meter I/O 9 low tariff
E 9.L
354
CNTR_IO10_LT
Meter I/O 10 low tariff
E10.L
355
CNTR_IO11_LT
Meter I/O 11 low tariff
E11.L
356
RTC_UTC
UTC time in seconds since January 1st 1970
UTC.T
357
EV_TIME
UTC time of last event
EVT.T
358
OPR_CNTR
Operating hour counter APLUS
OTC
359
OPR_CNTR1
Resettable operating hour counter 1
OTC1
360
OPR_CNTR2
Resettable operating hour counter 2
OTC2
361
OPR_CNTR3
Resettable operating hour counter 3
OTC3
362
RTC_LOCAL
Local time in seconds since January 1st 1970
LOC.T
363
H2_U1X
Voltage phase 1: content of 2nd harmonic
:
:
424
H63_U1X
Voltage phase 1: content of 63rd harmonic
425
H2_U2X
Voltage phase 2: content of 2nd harmonic
:
:
486
H63_U2X
Voltage phase 2: content of 63rd harmonic
487
H2_U3X
Voltage phase 3: content of 2nd harmonic
:
:
548
H63_U3X
Voltage phase 3: content of 63rd harmonic
549
H2_I1X
Current phase 1: content of 2nd harmonic
:
:
610
H63_I1X
Current phase 1: content of 63rd harmonic
611
H2_I2X
Current phase 2: content of 2nd harmonic
:
:
672
H63_I2X
Current phase 2: content of 63rd harmonic
673
H2_I3X
Current phase 3: content of 2nd harmonic
:
:
734
H63_I3X
Current phase 3: content of 63rd harmonic
735
H2_U1X_MAX
Voltage phase 1: max. content of 2nd harmonic
:
:
796
H63_U1X_MAX
Voltage phase 1: max. content of 63rd harmonic
797
H2_U2X_MAX
Voltage phase 2: max. content of 2nd harmonic
:
:
858
H63_U2X_MAX
Voltage phase 2: max. content of 63rd harmonic