Step 4. 

Rotate the SRD input shaft CCW until the key 

in the drive coupling comes into contact with the end of 
the key slot and the coupling just begins to turn. (Ref 
Photo 2). Upon contact, reverse the SRD input shaft ½ 
to ¾ of a turn to disengage the drive coupling key from 
the worm wheel. This will put a very small opening 
between the key slot and the drive coupling key. This is 
the SRD unit’s 

Home Position. 

(Ref Photo 3) 

Step 5. 

Set the SRD travel stop for the closed position (Home 

Position) by turning the bolt clockwise until the bolt comes into 
contact with the end of the worm wheel. Reverse the bolt ½ 
turn to ensure that the SRD travel stop is not used as the 
primary seating element for the pneumatic actuator. Tighten 
the lock/jam nut against the body of the override. (Note: If the 
SRD override has been optionally equipped with the Home 
Position Indicating Stop Bolt, the indicating head will be 
extended to indicate the SRD override is in the “Home 
Position”.

Step 6. 

Reposition the valve to the full open position using the 

pneumatic actuator. (Note: There should be no interruption of 
the 90 degree strike of the valve by the SRD or any other 
component. If there is an interruption, identify the problem and 
make the necessary corrections.) Set the

 

pneumatic actuator 

travel stop for the full valve and actuator open position. (Ref. 
Photo 5)

Содержание Dynatorque IOMSRD

Страница 1: ...override and the actuator mounting pad Apply a liberal amount of a liquid gasket material Cameron recommends using DOW Corning RTV 732 multi purpose sealant on both surfaces prior to SRD override installation Make sure to surround the mounting holes with sealant to assure a complete seal Installation The Cameron DYNATORQUE model SRD manual override operator offers safe and easy positioning of valv...

Страница 2: ...p bolt more than six to eight turns may allow the worm wheel and worm to disengage during the next phase of Step 1 Rotate the input shaft CW which in turn rotates the override output clockwise until the end of the key slot is just past centerline Ref Photo 1 Step 2 Install the SRD override in the valve and actuator assembly making sure that the valve and actuator are in the closed position Note Mo...

Страница 3: ...sed position Home Position by turning the bolt clockwise until the bolt comes into contact with the end of the worm wheel Reverse the bolt turn to ensure that the SRD travel stop is not used as the primary seating element for the pneumatic actuator Tighten the lock jam nut against the body of the override Note If the SRD override has been optionally equipped with the Home Position Indicating Stop ...

Страница 4: ...o confirm the proper setting of all components Stroke the valve and actuator assembly several times from closed to open to close to confirm proper pneumatic operation Note When the assembly is in the closed position the SRD input shaft should be able to be freely rotated to of a turn in the CCW direction if properly adjusted Note It is critical to the function of the assembly that the SRD be retur...

Страница 5: ... override the actuator rotate the handwheel counterclockwise for a fail closed actuator and clockwise for a fail open actuator The gearing is self locking so once the override position has been reached full CCW for a fail closed and full CW for a fail open the valve actuator and override can stay in this position until the air supply is restored Note When pneumatic actuator air has been restored t...

Страница 6: ... valve Assuming these components cycle fully the problem is probably the valve Check the valve for any obstructions If no obstructions are visible call the valve manufacturer for further information 2 If the pneumatic actuator and the override assembly do not appear to function properly make sure that the pneumatic actuator s spring is fully extended Never remove or separate the pneumatic actuator...

Страница 7: ... from your shipping documents acknowledgement or invoice here Part Number _________________________ Date Stamp _________________________ Located on the bottom of the operator housing Purchase Sales Order Number _________ DYNATORQUE Standard Grease Specification Alpha Green 2000 NLGI Grade Grade 2 EP Grease Base Calcium Sulfonate Color Green Anti Wear EP Additives Yes Dropping Point ASM D566 572Deg...

Отзывы: