VC-5MC-M/C110H User's Manual
Page 98 of 109
Command
Syntax
Return Value
Description
Set Timer Duration
Get Timer Duration
stdu n
gtdu
OK
n
Sets the duration of the
Timer output signal.
n: 1 – 60,000,000
㎲
Set Timer Delay
Get Timer Delay
stdl n
gtdl
OK
n
Sets the delay time for
the Timer.
n: 0 – 60,000,000
㎲
Reset Timer
rtmr
OK
Resets the Timer and
starts it again.
Get Timer Status
gtst
0|1|2
Displays the status of the
Timer.
0: Timer Idle
1: Timer Trigger Wait
2: Timer Active
Set Timer Trigger Source
Get Timer Trigger Source
stts 0|4|6|14|22|26
gtts
OK
0|4|6|14|22|26
Specifies a source signal
for the Timer output
signal.
0: Off
4: Frame Active
6: Exposure Active
22: Line0
26: Counter0Active
Set Timer Trigger
Activation
Get Timer Trigger
Activation
stta 0|1|2|3|4
gtta
OK
0|1|2|3|4
Sets the activation mode
for the Timer.
0: Falling Edge
1: Rising Edge
2: Level Low
3: Level High
4: Any Edge
Set AWB Offset X
Get AWB Offset X
swx n
gwx
OK
n
Sets a horizontal offset
from the origin to the
Data ROI.
Set AWB Offset Y
Get AWB Offset Y
swy n
gwy
OK
n
Sets a vertical offset from
the origin to the Data
ROI.
Set AWB Width
Get AWB Width
sww n
gww
OK
n
Sets a width for the Data
ROI.
Set AWB Height
Get AWB Height
swh n
gwh
OK
n
Sets a height for the Data
ROI.
Table 10-7 Command List #7