![CAMERA LINK Q-12A65 Скачать руководство пользователя страница 50](http://html.mh-extra.com/html/camera-link/q-12a65/q-12a65_operating-and-users-manual_487777050.webp)
OPERATING AND USER MANUAL QUARTZ SERIES
51
Mirror
9.2.5.
The output image can be mirrored horizontally, vertically and a combination of both.
Command
format: MIx
Command format: MI?
Return Message: x
Where x indicates the state of operation:
X
MIRROR FUNCTION
0
No mirror
1
Horizontal mirror
2
Vertical mirror
3
Horizontal and vertical mirror
In the processing order, the mirror function is applied after the ROI function has been performed.
Output resolution
9.2.6.
The output resolution is set by the OR command to be 8 bit or 10 bit.
Command format: ORx
Command format: OR?
Return Message: x
where x is 8 or 10, indicating number of bits.
NOTE:
The 3, 8 and 10 tap Camera Link formats only supports 8 bit pixel resolution. If the camera is
operated in eirther 3, 8 or 10 tap Camera Link configuration, the output resolution (OR) is pushed to 8
bit.
10 tap operation also pushes the maximum image resolution to 2000 (h) x 2048 (v) (Q-4A180) or 4080
(h) x 3072 (v) (Q-12A65).
See also output format command OFRM.
Region Of Interest
9.2.7.
The actual region of the sensor that is output to the interface can be configured.
The image format is set by the ROI command.
Command format: ROIl;t;w;h
Command format: ROI?
Return Message: l;t;w;h
where
l is the left most pixel.
t is the top pixel
w is the width of the ROI
h is the height of the ROI
Содержание Q-12A65
Страница 1: ...Operating and user manual QUARTZ SERIES CAMERA LINK MODELS ...
Страница 2: ...OPERATING AND USER MANUAL QUARTZ SERIES 2 ...
Страница 5: ...OPERATING AND USER MANUAL QUARTZ SERIES 6 ...
Страница 11: ...OPERATING AND USER MANUAL QUARTZ SERIES 12 ...
Страница 29: ...OPERATING AND USER MANUAL QUARTZ SERIES 30 ...
Страница 66: ...OPERATING AND USER MANUAL QUARTZ SERIES 67 ...