OPERATING AND USER MANUAL QUARTZ SERIES
19
Control of the camera
5.
Introduction
5.1
The Quartz cameras are fully software controlled via the Camera Link serial channel using a simple
ASCII based protocol.
It is possible to save settings as ‘power-up default settings’ in the camera.
A command line control application is available to interactively control the camera settings.
Please contact your local Business Office to obtain a copy of the latest release.
Although this is an easy way of changing camera settings, it is also possible to communicate with the
camera using self deployed software. Please refer to
chapter 5.2
for the communication protocol.
Use chapters 6 to 10
as a detailed reference of the control commands.
Communication protocol
5.2
The camera is controlled by a host system connected to the Camera Link interface using the serial
communication link of the Camera Link. Commands and resulting data are transferred between the
host system and the camera by means of a communication protocol. The host system is the master
in the communication link. All actions are initiated by the host system.The camera only replies to a
message received from the host system.
Data link settings
5.2.1.
The data link settings that shall be used for communication with the camera are:
Baud rate
57600 baud
stop bit
1
data bit
8
parity
none
handsha king none
Data flow characters
5.2.2.
The communication protocol uses data flow control characters to identify a message and for
acknowledgement.
The following data flow characters are defined:
CHAR
DEC
DESCRIPTION
NUL
0
NUL character, is ignored
STX
64
start of message identifier
ETX
13
end of message identifier
ACK
6
positive acknowledgement
NAK
21
negative acknowledgement
Message Format
5.2.3.
Command and data are packed in a message. A message starts with the STX character followed
by the message content. The message ends with an ETX character. The characters allowed in the
message content range from decimal 32 to 255.
Format: STX <message content> ETX
Содержание Q-12A65
Страница 1: ...Operating and user manual QUARTZ SERIES CAMERA LINK MODELS ...
Страница 2: ...OPERATING AND USER MANUAL QUARTZ SERIES 2 ...
Страница 5: ...OPERATING AND USER MANUAL QUARTZ SERIES 6 ...
Страница 11: ...OPERATING AND USER MANUAL QUARTZ SERIES 12 ...
Страница 29: ...OPERATING AND USER MANUAL QUARTZ SERIES 30 ...
Страница 66: ...OPERATING AND USER MANUAL QUARTZ SERIES 67 ...