Phrontier Technologies
PHIRE User Manual V4
11
With Mounting Flange Options
7. Trouble Shooting:
Although the PHIRETM products are designed to be plug-and-play and user friendly, users may
encounter some abnormal system operations in practice. The table below lists some possible
abnormal operations that can be easily corrected by users before sending the units back to our
technical support for investigation.
LED INDICATORS
POSSIBLE CAUSES
CORRECTION PROCEDURES
PHIRE-
CM
PHIRE-
FG
G
reen
L
ED
R
ed
L
ED
G
reen
L
ED
R
ed
L
ED
1 ON ON ON OFF a) Initialization failure
a) Reset the PHIRE-CM power
2 ON OFF ON ON a) Initialization failure
a) Reset the PHIRE-FG power
3 Blink OFF Blink OFF a) Camera is not on
b) PHIRE-CM module is not
connected securely
a) Check camera power and make sure
the camera is functioning correctly
b) Inspect/secure PHIRE-CM connection
4 ON OFF Blink OFF a) Camera malfunction after
PHIRE initialized
b) Insecure PHIRE-CM
connection after initialization
a) Inspect/secure PHIRE-CM connection
b) Reset camera and PHIRE system
5 OFF OFF Blink Blink a) PHIRE-CM no power
b) Fuse burn off on the CM
module, possible causes
including current or voltage surge
from direct DC power on or due
to improper electrical grounding.
a) Check PHIRE-CM power connection
and reset camera and PHIRE system
b) Send back the unit to Phrontier Tech
or authorized distributors for fuse
replacement
D-A-CH
Laser 2000 GmbH
82234 Wessling
Tel. +49 8153 405-0
[email protected]
www.laser2000.de
FrAnCe – Telecom
Laser 2000 SAS
78860 St-N. l. Bretèche
Tel. +33 1 30 80 00 60
[email protected]
www.laser2000.fr
FrAnCe – Photonic
Laser 2000 SAS
33600 Pessac
Tel. +33 5 57 10 92 80
[email protected]
www.laser2000.fr
IberIA
Laser 2000 SAS
28034 Madrid
Tel. +34 617 308 236
[email protected]
www.laser2000.es
norDICs
Laser 2000 GmbH
112 51 Stockholm
Tel. +46 8 555 36 235
[email protected]
www.laser2000.se