M08627;23/39
- 23 -
[Description of CR data]
Bit
Abbrev.
Content
Logic
Remark
0
MNI
Disabled display of menu screen
1: Disabled (OFF)
1
BZI
Disabled buzzer output
1: Disabled (OFF)
2
TPEN
ON/OFF selection for test pattern
1: Test pattern ON
3
DFRM
Selection of output data format
1: 8bit format
0: 10bit format(Default)
4
-
(Not used)
5
TWEN
Double pulse
・
asynchronous shutter
1: Enabled
6
STRBC
Enabled STRB signal output for continuous shutter 1: Enabled
7
CC1P
Selection of trigger signal (Vinit2) polarity via CC1
1: Positive polarity
8
-
(Not used)
No change can be
executed
by
a
communication
command.
(Readout is possible.)
9
BAUD
9600bps/19200bps
selection
for
serial
communication baud rate
1=19200bps
10 -
(Not used)
11 -
(Not used)
12 -
(Not used)
13 -
(Not used)
14 -
(Not used)
15 DEFR
Request for reading out default value at next start-up 1: Request
(Note) All the items of the CR data are “0” as factory default.
[Description of FR data]
Bit Abbrev.
Content
Logic
Remark
0 ASYE
Selection of continuous/asynchronous
shutter
1: Asynchronous (ASYNC)
1 PWCE
Selection of enabled/disabled for pulse
width control
1: Enabled pulse width control
2 LEXE
Selection of high speed/low speed shutter 1: Low speed shutter
3 PSCE
Selection of normal scan/partial scan
1: Partial scan
Selection of DRFT is put
ahead of PSCE
4 DRFT
Selection of draft scan ON/OFF
1: Draft scan ON
5 FDUMP Selection of fast dump ON/OFF
1:Fast dump ON
6 -
(Not used)
7 -
(Not used)
8 ESP(0)
Externally
designated
shutter
speed
position
H'0 to H'9 or H'F
Where ESPE=1, externally
designated number from 0
to 9 (designated position)
is reflected.
In case of H'F, external
shutter speed in H unit is
selected.
9 ESP(1)
10 ESP(2)
11 ESP(3)
12 ESPE
Effectiveness of externally designated
shutter speed
1: Effective
13 -
(Not used)
14 -
(Not used)
15 AGCE
Selection of MGC/AGC operation
1: AGC
(Note)
All the items of the FR data are “0” as factory default.
(Example) If “MF=H’0080.0003” is displayed on the menu screen, the camera is in the following state (converting the
numbers to ones in binary system):
H’00=B’00000000, H’10=B’10000000 and H’03=00000011 are substituted to the above numbers.
CR=B’0000000010000000, FR=B’0000000000000011
………
CR(7)=FR(1)=FR(0)=1, All other bits = 0
(Where CR(n) and FR(m) represent the nth bit of CR and mth bit of FR respectively)
Based on 1 or 0 of these bits and the information in the above table, the user can know that the camera is in the
state of “Vint2= Positive polarity”, “ASYNC” and “Enabled pulse width control”.
[Explanation]
The setting values (1 or 0 of respective bits) of (CR) and (FR) vary according to the change to be made using the switches
on the rear panel of the camera. The operation modes that cannot be changed by the RS-232C commands can be
changed by altering the bits of (CR) and (FR).
(Example 1) When a change is made from the continuous shutter mode
→
asynchronous shutter mode,
“MF=0000.0000” is replaced by “MF=0000.0001” (ASYE bit = 1).
(Example 2) When CR (0) is changed from 0
→
1 using a serial communication command, “ON” on the menu display is
replaced by “OFF” (MIND=1).
(Example 3) When FR (3) is changed from 0
→
1 using a serial communication command, the scan mode changes
from Normal scan mode to Draft scan mode,