Tools and materials
Make sure you have all the tools and materials you will need for installing in total safety and in compliance with applicable
regulations. The figure shows some of the equipment installers will need.
GENERAL INSTRUCTIONS FOR INSTALLING
⚠
Only skilled, qualified staff must install this product.
⚠
Warning! Before working on the control panel, cut off the main current supply and, if present, remove any batteries.
Preliminary checks
⚠
Before beginning the installation, do the following:
• make sure that the point where the control panel is fastened is protected from any impacts and that the anchoring surface
is solid enough, and that proper tools are used (that is, screws, anchors, and so on);
• make sure you have set up a suitable dual pole cut off device along the power supply that is compliant with the installation
rules. It should completely cut off the power supply according to category III surcharge conditions (that is, with minimum
contact openings of 3 mm);
•
make sure that any connections inside the container (ones that ensure continuity to the protection circuit) are fitted with
additional insulation with respect to those of other electrical parts inside:
• set up suitable tubes and conduits for the electric cables to pass through, making sure they are protected from any
mechanical damage.
Cable types and minimum thicknesses
Connection
Cable type
Cable length
1 < 10 m
Cable length
10 < 20 m
Cable length
20 < 30 m
Control panel power supply 230 V AC
FROR CEI
20-22
CEI EN
50267-2-1
3G x 1.5 mm
2
3G x 2.5 mm
2
3G x 4 mm
2
Motor/encoder power supply 24 V DC
3 x 1 mm
2
3 x 1.5 mm
2
3 x 2.5 mm
2
Flashing light
2 x 0.5 mm
2
Photocell transmitters
2 x 0.5 mm
2
2 x 0.5 mm
2
2 x 0.5 mm
2
Photocell receivers
4 x 0.5 mm
2
4 x 0.5 mm
2
4 x 0.5 mm
2
Command and safety device
2 x 0.5 mm
2
2 x 0.5 mm
2
2 x 0.5 mm
2
Antenna
RG58
max 10 m
If cable lengths differ from those specified in the table, establish the cable sections depending on the actual power draw
of the connected devices and according to the provisions of regulation CEI EN 60204-1.
For multiple, sequential loads along the same line, the dimensions on the table need to be recalculated according to the actual
power draw and distances. If connecting products that are not contemplated in this manual, see the literature accompanying
said products