ENGLISH

1) Keep the CH1 button on the electronic card pressed. The LED fl ashes.

2) Press the transmitter button you wish to memorise. The LED will stay on to show memorisation has been successful.

LED flashing

LED on

11.4 - MEMORISATION

CH1 

= Channel for direct command to a function of the the gearmotor’s card, (“open only / “open-close-invert” or “open-stop-close-stop” 

command, depending on the choice made on DIP switches 2 and 3). 

CH2 

= Channel for direct command an accessory device connected to B1-B2.

3) Repeat the points 1 and 2 procedures for the “CH2” button associating this to another button on the transmitter.

Содержание ZL180 SERIES

Страница 1: ...ZL180 SERIES INSTALLATION MANUAL ZL180 CONTROL PANEL FOR 24V OPERATORS English EN...

Страница 2: ...nd controls the following functions automatic closing after an open command pre flashing by the motion indicator obstacle detection when gate is still in any position continual monitoring of photocell...

Страница 3: ...g on the machinery cut off the main power supply and disconnect any emergency batteries 1 Transformer 2 Control unit fuse 3 Trimmers see page 9 4 Buttons for memorising the radio code 5 Plug for the r...

Страница 4: ...tted with extra insulation as compared to the other conductive parts inside Make sure you have suitable tubing and conduits for the electrical cables to pass through and be protected against mechanica...

Страница 5: ...ctual power draw from the connected devices and according to the CEI EN 60204 1 standards For connections that require several sequential loads the sizes given on the table must be re evaluated based...

Страница 6: ...e following accessories 24 V AC normally alternated power 24 V AC continuous power when the emergency batteries are in operation Overall power allowed 34 W Power supply 230 V AC 50 60 Hz 6 4 POWER SUP...

Страница 7: ...24V DC gearmotor featuring delayed action on opening M1 Left hand installed inside view Standard installation A3024N A5024N gearmotors RA RA Opening speed blocker microswitch RC RC Closing speed redu...

Страница 8: ...k F7024N gearmotors RA RA Microswitch Opening programmable RA RA Opening speed blocker microswitch RC RC Closing speed reduction microswitch M red N black F7024N gearmotors 24V DC gearmotor featuring...

Страница 9: ...gearmotors 2 leaved gates With only one gearmotor one leaved gates M2 gearmotor do the following he following a a Set Set dip switches 4 and 6 to ON dip switches 4 and 6 to ON and dip switches 1 2 3 5...

Страница 10: ...Mode 2 Does not allow connection of an indicator lamp on 10 5 after connection it a a Set Set dip switches 2 and 6 to ON dip switches 2 and 6 to ON and dip switches 1 3 4 5 to OFF b b c c d d continu...

Страница 11: ...uring closing N C socket Input for safety devices such as photocells sensitive edges and other EN 12978 compliant devices When gate leaves are closing opening the contact causes reversal until total o...

Страница 12: ...as just made see selecting functions dips 2 and 3 Key selector and or partial opening button N O socket Opening of one gate leaf to allow pedestrian passage 6 7 COMMAND DEVICES At each opening and clo...

Страница 13: ...g gate closing the gate motion is inverted until total opening is reached connect the safety device to terminals 2 C1 sif not used set DIP switch to ON 8 OFF Partial stop stops gate when an obstacle i...

Страница 14: ...signed to the opening endstop see paragraph 6 4 page 7 the adjustment settings will be the following Opening Stop default function CLOSING ENDSTOP ATI gearmotors However if it intervenes activating th...

Страница 15: ...ch above Upper cam Lower cam Lower cam fixing and locking release screw Upper cam fixing and locking release screws ENDSTOP ASSEMBLY FAST gearmotors WARNING Make sure you have inverted the M N connect...

Страница 16: ...is released Secure the cam by tightening the lateral screws N B The closing endstop can be adjusted after setting the opening microswitch Warning the upper cam of the operator s endstop assembly is c...

Страница 17: ...time and without obligation on CAME cancelli automatici s p a to notify users ENGLISH OPENING ENDSTOP RIGHTHAND GEARMOTOR INSIDE VIEW Remove the screws from the upper cam and turn it upsidedown Releas...

Страница 18: ...ral screws Release the gearmotor and fully close the gate leaf N B Always first adjust the opening endstop and then the closing endstop Warning the upper cam of the operator s endstop assembly is cali...

Страница 19: ...cells connected to REOPEN DURING CLOSING or non operation of the same C3 Yellow LED Normally off When it is on and with the PROG LED blinking it warns of objects detected by the photocells connected t...

Страница 20: ...O AT01 AT02 AT04 CAME CAME CAME TWIN TWIN2 TWIN4 Pag 20 20 Manual code 319U17 319U17 ver 12 12 04 20109 CAME cancelli automatici s p a The data and information reported in this installation manual are...

Страница 21: ...The LED flashes 2 Press the transmitter button you wish to memorise The LED will stay on to show memorisation has been successful LED flashing LED on 11 4 MEMORISATION CH1 Channel for direct command t...