ENGLISH

10 WAY DIP SWITCH

2 WAY DIP SWITCH

1 OFF 

Enables the obstacle stand-by or partial stop function; connect the safety device to terminals [2-CY]. If device is unused, 
set the DIP switch to ON;

1 OFF - 2 ON  

Obstacle stand-by

 – stops the gate when there is an obstacle is detected by the safety device; once the 

obstacle has been cleared, the gate is automatically set back in motion to finish initial run. Connect the safety 
devices to terminal [2-CY];

1 OFF - 2 OFF   

Partial stop

 – stops gate  when an obstacle is detected by the safety devices; once the obstacle is cleared, the 

gate remains still or closes if the automatic closing function is enabled. Connect the safety devices to terminal 
[2-CY];

1 ON - 

Automatic closing

 - the automatic closing timer is activated when on opening the gate leaf has reached the full open 

stroke. The time is preset and adjustable, and is subject to the action of any safety devices. It does not activate after a 
total safety “stop” or during a power outage;

2 ON - 

“Open-stop-close-stop”

 function with button [2-7] and remote control (with built-in radiofrequency card);

2 OFF - 

“open-close-inversion”

 function with button [2-7] and remote control (with built-in radiofrequency card);

3 ON - 

“Open only”

 function with remote control (featuring built-in radiofrequency card);

4 ON - 

Pre-Flashing during opening and closing

 - Following an opening or closing command, the flasher connected to [10-E], 

flashes for 5 seconds before initiating the operation;

5 ON - 

Obstacle detection

 - When motor is idle (gate closed, open or after a total stop command), it prevents any motion if the 

safety devices (e.g. photocells) detect any obstacle;

6 ON - 

Maintained action

 - the gate works by keeping the button pressed (one button [2-3] for opening, and one button [2-4] 

for closing);

7 ON -  Enables to the 

command of A1824 operators

;

7 OFF -  Enables to the 

command of FROG J operators

;

8 ON - 

Operation of the photocells safety test

 - this allows the card to assess the efficiency of the safety devices (photocells) 

after each opening and closing command;

9 OFF - 

Total stop

 - this function halts the gate, consequently  excluding any closing cycle; press buttons or remote control to 

set back in motion. Insert safety devices on 1-2]; if not used, set DIP switch to ON;

10 OFF - 

Reopening during closing

 - if the photocells detect an obstacle during gate closing, the gate motion is inverted until 

total opening is reached; connect the safety device to terminals [2-CX];

NB -Dip switches 3 and 6 are used, independently, also to activate the electrolock and ram blow (page 7). 

7 Selecting functions

Содержание Z 24 Series

Страница 1: ...Z 24 SERIES INSTALLATION MANUAL ZL90 CONTROL PANEL FOR 24V OPERATORS English EN...

Страница 2: ...II Material ABS Protection rating IP54 operating temperature 20 55 C This product is engineered and manufactured by CAME cancelli automatici s p a and complies with current safety regulations Guarante...

Страница 3: ...2 M1 motor fuse 3 M2 motor fuse 4 Line fuse 5 Accessories fuse 6 Control unit fuse 8 Buttons for calibrating the stroke 8 Buttons for memorising the radio code 9 Control and signalling LED unit 10 Fun...

Страница 4: ...with extra insulation as compared to the other conductive parts inside Make sure you have suitable tubing and conduits for the electrical cables to pass through and be protected against mechanical dam...

Страница 5: ...rom the connected devices and according to the CEI EN 60204 1 standards For connections that require several sequential loads the sizes given on the table must be re evaluated based on actual power dr...

Страница 6: ...GLISH Power supply 230V a c 50 60 Hz Terminals for powering the following accessories 24V a c normally alternated power 24V a c continuous power when the emergency batte ries are in operation Overall...

Страница 7: ...c when the led stays on after about 5 seconds the procedure is complete d set to the dip switches back to OFF or to the previous position which depends on the functions selection see paragraph 7 page...

Страница 8: ...causes reversal until total opening is obtained partial stop N C socket input for safety devices such as photocells sensitive edges and other EN 12978 compliant devices Halts mo ving gate leaves and...

Страница 9: ...ivate test operation IMPORTANT when running the safety test function the N C contacts if unused should be excluded on the relative DIP switches see chapter 7 selecting functions 6 8 ELECTRICAL CONNECT...

Страница 10: ...p function with button 2 7 and remote control with built in radiofrequency card 2 OFF open close inversion function with button 2 7 and remote control with built in radiofrequency card 3 ON Open only...

Страница 11: ...ocells that are set to the PARTIAL STOP or OBSTACLE STAND BY function Led CY Led PROG Led ALIM Led STOP Led CX TH 9 Signal LED Trimmer ACT Adjusts the waiting time when gate is open Once this time has...

Страница 12: ...to be half way open block the gearmotors again 10 1 PRELIMINARY ASSESSMENT OF THE DIRECTION OF MOVEMENT DURING OPENING Otherwise 1 if the gate leaves close invert the M N phases on either of the gear...

Страница 13: ...TIC CALIBRATION OF THE GEARMOTORS The gate leaf of the second gearmotor perform a closing run and an opening run With gate leaves fully ope the PROG LED stays on for some seconds to show the proper au...

Страница 14: ...a to notify users ENGLISH 11 Activating the remote control AF card Lock the radiofrequency card into the electronic card AFTER CUTTING OFF THE POWER SUPPLY or after disconnecting the batte ries N B t...

Страница 15: ...i s p a to notify users ENGLISH 11 3 TRANSMITTERS CAME CAME CAME CAME CAME CAME CAME CAME CAME CAME TOUCH TCH 4024 TCH 4048 TOP TOP 432NA TOP 434NA TOP 432S TOP TOP 302A TOP 304A TOP TOP 432A TOP 434A...

Страница 16: ...onic card pressed The LED ashes 2 Press the transmitter button you wish to memorise The LED will stay on to show memorisation has been successful LED flashing LED on 11 4 MEMORISATION CH1 Channel for...

Страница 17: ...98 37 EC CAME Cancelli Automatici S p A via Martiri della Libert 15 31030 Dosson di Casier Treviso ITALY tel 39 0422 4940 fax 39 0422 4941 internet www came it e mail info came it Declares under its o...

Страница 18: ...1 237 Warszawa Warszawa POLAND 48 22 8365076 48 22 8363296 CAME United Kingdom Ltd CAME United Kingdom Ltd Unit 3 Orchard Business Park Town Street Sandiacre Nottingham Nottingham Ng10 5du UNITED KING...

Отзывы: