Example set-up with VA/01
L1
L2
L3
Lb
La
1
2
PLX V Wi-Fi
1
2
PLX V Wi-Fi
XDV/304
VA/01
1
2
PLX V Wi-Fi
SLAVE
PLX V Wi-Fi
1
2
ON
KIT
1
2
KIT
KIT
KIT
SLAVE
SLAVE
SLAVE
1
2
ON
1
2
ON
1
2
ON
1
3
4
2
Cable length
Section
Cable type
La, Lb
VCM/1D or UTP CAT5
L1, L2, L3
VCM/2D
Section
Maximum section length
La + Lb
100 with VCM/1D
30 with UTP CAT5
L1 + L2 + L3
300
La + Lb + L1 (L2, L3)
150
La + Lb + L1 + L2 + L3
600
Maximum number of internal receivers per cable type
VCM/1D
UTP CAT5
Wi-Fi PLX V (MASTER)
1
1
SLAVE RECEIVERS
1
1
The SLAVE receiver is a generic low-consumption receiver. The closing resistor must
be activated on the last one in the row.