Dip 10-way
SELECTION FUNCTIONS
1
ON
Parameter storage (used during calibration pag. 17).
2
ON
Checking the charge level on the emergency (whit MA7032, see pag.18).
3
-
Not used, keep the dip in position "OFF».
4
ON
Constant push while closing
5
ON
"Step-by-step" operation (see contact 2-M, pag.14).
6
ON
Interface with other automation system (see "installing the interface system" pag.20).
7/8
ON
Disabled electric lock (see pag.19).
7
ON
Continuous operation of lock (locks doors open and dosed) see pag.19
8
OFF
7
OFF
Continuous operation of lock (locks doors closed) see pag 19
8
ON
7/8
OFF
Electric lock disengaged from local control (controlled by function switch MA7041) pag.19
9/10
ON
Emergency system doses doors in case of power failure (see pag.18)
9
OFF
Emergency system opens doors in case of power failure (see pag.18)
10
ON
9/10
OFF
Normal operation powered by emergency battery in case of power failure (see pag.18)
Dip 4-way
SELECTION FUNCTIONS
1
ON
Activation of spring-loaded anti-panic device (set dip switch 4 to ON, conslant push while dosing,
1Q-dip function selector, see pag.19).
2
-
Not used, keep the dip in position "OFF»
3
ON
Exdudes the photoelectric cell function (MF9011 or MF9111 card inserted into the control board,
pag.22)
4
-
Not used, keep the dip in position "OFF»
FUNCTIONS
OF INDICATOR
LED
~
C0~CDCDCD~CDCD
: tlE
1
2 3
4
5 6 7 8
._--
_.
LED
STATUS
SIGNAL
1
flashing
-Encoder is inoperative
1
lit
-Encoder is inoperative
2
(')
-<!mergency battery is discharged
3
lit
-pilot light on 24V a.c.
4
lit
-photocell contact open
5
lit
-interface function aclivated (see "installing the interface-)
6
lit
,
-malfunction on electnck lock
7
lit
-pilot light on amperometnc sensor
8
flashing
-automatic closing cycle in progress
8
flashing
-"read- error during automatic calibration cycle
6/7/8
lits
-automatic calibration procedure terminated
('J in this case, the LED signal remains lit to indicate that the anti-panic device ballenes are run down only if the
emergency ballery status check is disabled (1o-way dip 2 set
10
OFF); whereas it flashes if the battery check is activated
(10-way dip 2 set to ON).
,