background image

s.r~

R()Pf()

IPS

ELECTRICAL CABINET

t--

__

The

APRE

key, starts automation and completes an opening cycle.

Attention: The function of the open key is excluded if dip switch 5

(10-way module) is set to ON.

t----

The

RESET

key. resets the data and restarts the automation in

question.

@@@

6

7

8

RESET

~

MA70n

-11111111

~g;JOO]

L()

APRE

IMPORTANT:

Do not perform the following operations. electrical connections/wiring

or replacement

of circuit cards unless the

mains power has been disconnected

and the

"+"

(red) power terminal has been removed from the emergency

battery (if installed).

ADJUSTMENT

TRIMMERS

(II

UUU0 U

111)--MF9011-MF9111

-[10011

0 0 0 01)

~

~=

ttl

V.RALLAP.

ADJUSTMENTS TRIMMERS

N'

1

2

3

4

5

6

7

8

9

,

STAAT

START

BRA.KI,'I(;

PONT()f

AAClM'\.

SlCMtlO.

PONT Of.

INTENSITY IN

SlOWDO.

FUCT1CN

9PENII'K;

"'<mAl

TIC

WN

CLOSING

SPEED

OPENING

SPEED

ClOSIt\'G

THE IN'TW

WN

Sl<;MOO.

OtlfNI/'.IG

QOSING

QOSING

SlCMtJO.

SlCMtlOWN

OPENING

WN

WN

PHASE

STAlmNG

0.5

+

13

5

+ 12

RODEO I

RODEO 2

C()RS,\ 1

CORSA 2

STARTING

5

+ 12

VAlUE

PONT

fJj+90%

SEC

CM'SEC.

6.6+55

17.2+76

8.6+55

17.2+78

POINT

CNvSEC

CMf.;EC

CMf.;EC.

CMf.;EC.

CMf.;EC.

"

Содержание RODEO

Страница 1: ...IES RODEO AUTOMATION SYSTEM FOR SLIDING DOORS M71 rClY 3 1 0712000 CAME CANCELJ I AUTO na 19PM7iJ AUTOMATION SYSTEM FOR SLIDING DOORS WITH MICROPROCESSOR CONTROL _ for door wings weighting I up to 125kg each I ...

Страница 2: ...talled S M 2 Rl Normally open contact N O external sensor can be excluded S R2 2 R2 Normally open contact N O internal sensor Rl 2 M Normally open contact N O for step by step operation e 2 manual button I AI c Contact 1 2 and 2 C1 are normally closed N C and bridged together at the factory To use these functions replace the bridge connections with the relative devices The 2 el contact is used whe...

Страница 3: ...ess the mains power has been disconnected and the red power terminal has been removed from the emergency battery if installed ADJUSTMENT TRIMMERS IIUUU0 U111 MF9011 MF9111 10011 0 0 0 01 ttl V RALLAP ADJUSTMENTS TRIMMERS N 1 2 3 4 5 6 7 8 9 STAAT START BRA KI I PONT f AAClM SlCMtlO PONT Of INTENSITY IN SlOWDO FUCT1CN 9PENII K mAl TIC WN CLOSING SPEED OPENING SPEED ClOSIt G THE IN TW WN Sl MOO Otlf...

Страница 4: ...way SELECTION FUNCTIONS 1 ON Activation of spring loaded anti panic device set dip switch 4 to ON conslant push while dosing 1Q dip function selector see pag 19 2 Not used keep the dip in position OFF 3 ON Exdudes the photoelectric cell function MF9011 or MF9111 card inserted into the control board pag 22 4 Not used keep the dip in position OFF FUNCTIONS OF INDICATOR LED C0 CDCDCD CDCD tlE 1 2 3 4...

Страница 5: ...esired delay before automatic closing 9 Trimmer 2 can be adjusted only if function switch MA7041 has been installed and if this switch has been set to the partial opening position 10 Use the lever on the manual release system to re arm the electric lock if installed 0 If the automation system stops during the closing cycle the motor polarity may be incorrect If this occurs proceed as follows Disco...

Страница 6: ...71 SOLA MA7041 M19011 Mf9111 1I1111l11 23456 7 Note in case the MA 7041 selector is not connected and you wish to activate the antipanic function bond contacts 1 3 as shown in the figure Anti panic device with constant battery control Setting dip switch 2 of the 10 way module to the ON position on the interlock system set it on both panels activates the constant control of the battery charge buffe...

Страница 7: ...e unit locks on closure and is released electrically when the open command is given_ This is the default setting Locking with doors closed and open The unit locks both when open and closed when positioned correctly 1 and is released electrically by each open and close command Delayed locking The electric lock is unlocked when the first open command is given at initial start up or after a power fai...

Отзывы: