EN
- 07/2019 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - T
ranslation of the
original instructions
PROGRAMMING
F 2
OUT1 command mode
F 3
OUT2 command mode
F 4
OUT3 command mode
F 5
OUT4 command mode
F 6
OUT1 command duration
F 7
OUT2 command duration
F 8
OUT3 command duration
F 9
OUT4 command duration
F 10 CRP address
F 11 RS485 serial-bus speed
F 12 Set clock
F 13 Store in Memory Roll
F 14 Copy from Memory Roll
F 15 Rolling Code store mode
F 16 PIN
U 1
Store Users
U 2 Delete Users
U 3
Delete all users
U 4
Code Decoding
A 4
Reset
H 1
Firmware version
Menu map
Function
Descripton (
the default values appear with a black backdrop)
F 2
OUT1 command mode
. To choose the output's command mode.
[ ] Maintained Action Mode.
[ ] Timer Mode 1 <−> 60 seconds.
[ ] Timer Mode 1 <−> 180 minutes.
[ ] Step-by-Step Mode.
F 3
OUT2 command mode
. See [ F 2 ].
F 4
OUT3 command mode
. See [ F 2 ].
F 5
OUT4 command mode
. See [ F 2 ].
F 6
OUT1 command duration.
To set the duration of the timer command, if it is set.
[ …<−>…
] Seconds / [ …<−>…
] Minutes
F 7
OUT2 command duration.
See [ F 6 ].
F 8
OUT3 command duration.
See [ F 6 ].
The key is
for
•
entering the programming
•
entering single menus
•
confirming/saving the values you have set
The keys
are for
•
moving from one item to another
•
increasing or decreasing values
The key is
for exiting the menus without saving
any changes
Page
8
- Manual
FA01357-
EN
- 07/2019 - © CAME S.p.A. - The contents of this manual may be changed, at any time, and without notice. - Original instructi
ons