INSTALLING
Fitting
Place the casing where it is protected, and at least fi ve meters from any other receivers; and place the antenna
as high and as far as possible from any metal or reinforced concrete structures.
Use ø 6 cylinder head screws and suitable cable glands to ensure the IP is held fast.
Fit suitable cable glands, by drilling the marked inputs under the control panel.
Be careful not to damage the control board.
Technical data
Type
RBE4024
RBE4230
Protection rating (IP)
54
54
Power supply (V)
24 AC/DC
120 - 230 AC
Frequency (Hz)
/
50/60
Stand-by consumption (W)
0.43
0.67 - 0.8
Maximum power (W)
4.4
3 - 3.2
Relay contact rating - resistive load cosφ=1 (A/V)
5 / 230
5 / 230
Relay contact rating - (A/V) inductive load
1.5 / 230
1.5 / 230
Casing material
ABS
ABS
Operating temperature (°C)
-20 ÷ +55
-20 ÷ +55
Apparatus class
|||
II
Weight (Kg)
0.55
0.6
Fuses
RBE4024
RBE4230
- Line (mA)
315 T
315 T