LED-SIGNALS

The ORANGE LED 
fl ashes 1 x 
every 3 seconds.

Bad calibration

The ORANGE LED is 
on permanently.

The ORANGE LED 
fl ashes quickly.

The RED or GREEN 
LED is ON sporadicly 
or permanently. 

Launch a calibration.

Send the sensor back for a technical check-up.

Corfi rm the DIP-switch setting: 
long push on the push button.

Cut and restore power supply.
If orange LED fl ashes again, replace sensor.

The sensor does not 
react, but a calibration 
can be launched.

Chech wiring. 
- Door control with test: 
  Connect RED and BLUE wires to test output.
- Door control without test: 
  Connect BLUE to 0 V and RED to +12 V - 30 V DC.

The ORANGE LED 
fl ashes 2 x 
every 3 seconds.

The ORANGE LED 
fl ashes 3 x 
every 3 seconds.

The ORANGE LED 
fl ashes 4 x 
every 3 seconds.

The ORANGE LED 
fl ashes 5 x 
every 3 seconds.

Check power supply (tension, capacity).
Reduce the cable length or change cable.

Check wiring between modules.
Launch a module count: long push on push button 
of MASTER.

Launch a new calibration. 
Step out of the detection fi eld.
Change angle of spots.
Switch off background (DIP 3: OFF).

Power supply is out of limit.

The sensor signals an 
internal fault.

Bad adjustment of the 
uncovered zone.

The monitoring is activated, 
but the test input is not 
powered.

Communication error 
between modules.

The sensor receives 
not enough IR-energy.

The sensor encounters a 
memory problem.

DIP-switch setting 
awaiting confi rmation.

The sensor is disturbed by 
lamps or another sensor.

Select a different frequency for each module (DIP 2).
Launch a calibration.

Calibration error

Check mounting height.
Change position of calibration screw. 
Launch a new calibration.
Switch off background (DIP3: OFF)

Check if the DIP-switch 4 is in correct position.
Launch a calibration.

CAME hereby declares that MR8534/MR8570/MR8590 is in conformity with the basic requirements and the other 
relevant provisions of the directives 1999/5/EC, 2004/108/EC and 2006/42/CE.
Only for EC countries: According to the European Guideline 2002/96/EC for Waste Electrical and Electronic Equipment 
(WEEE)
Original upon request.

BUY

-

TO

-

SELL

 

PRODUCT

 

SAFETY INSTRUCTIONS

The manufacturer of the door system is responsible for carrying out a risk assessment and installing the sensor and the door system
in compliance with applicable national and international regulations and standards on door safety and if applicable, the machinery directive 2006/42/EC. 

Only trained and qualifi ed personnel may install and setup the sensor. The warranty is void if unauthorized repairs are made or attempted by unauthorized personnel. Avoid 
touching any electronic and optical components.

M

R

8

5

3

4

-7

0

-9

0

 / F

A

0

0

0

2

6

M

0

O

riginal

 in

s

tr

u

c

tion

s

 4

S

A

F

E / 4

2

.8

2

8

0 / v

1

 - 0

2

.1

5

Отзывы: