4

6

5

4

5

X

M

R

8

5

3

4

-7

0

-9

0

 / F

A

0

0

0

2

6

M

0

☜☞

 4

S

A

F

E / 4

2

.8

2

8

0 / v

1

 - 0

2

.1

5

SETTINGS

DOOR SAFETY CHECK

CALIBRATION

IMPORTANT

: Test the good 

functioning of the installation 
before leaving the premises.

If necessary, position spots 
closer to or away from the door 
and 

relaunch a calibration

.

After changing a DIP-switch, the orange LED fl ashes. 

A LONG push on the push button of the 

MASTER

 

confi rms the settings of ALL MODULES.

Afterwards, a number of green fl ashes (x) indicates 
the number of connected modules.

A SHORT push on the button of the 

MASTER

 launches a 

calibration on ALL MODULES.

Do not stand in the detection fi eld!

When the LED is off on all modules, the detection zone is OK.

The detection zone is too short: 
turn the screw clockwise.

The detection zone is too long: 
turn the screw anticlockwise.

Step out of the detection fi eld. 
If necessary, change angle or switch off background (DIP 3 = OFF).

Launch a new calibration. 

The fl ashing speed of 
the LED increases when 
approaching the optimal 
position.

MOUNTING

 SIDE

FREQUENCY

BACKGROUND

UNCOVERED 

ZONE

RELAY 1

STOP

RELAY 2

REOPENING

FREQ A

FREQ B

ON

OFF

HIGH*

LOW

ON

OFF

LED during detection:
R1 > RED
R2 > GREEN

Set different 
frequencies on 
modules close to 
each other.

Not enough background 
refl ectivity: switch to OFF

Approximate values at 2 m:
high= 30 cm, low = 15 cm

RED-GREEN

OFF

GREEN

RED

ORANGE

ORANGE

GREEN

OFF

FACTORY VALUE

* Recommended for most applications.
   Moutning height > 3 m: set to LOW for 
   EN 16005 and DIN 18650-conformity.