3
4
P
A
XXS
XS
S
>
>
>
>
L
XL
XXL
1
2
>
>
>
>
>
... S,
XS
,
XXS
...
L
,
XL
,
XXL
< 3 m
> 3 m
+
MECHANICAL ADJUSTMENTS
SETTINGS
(by remote control or push buttons)
FIELD SIZE
FIELD SIZE
IMMUNITY FILTER
DETECTION MODE
OUTPUT
CONFIGURATION
bi = two-way detection; uni = one-way detection towards sensor
A = active output (NO-contact)
P = passive output (NC-contact)
bi
uni
uni
PRM
FACTORY VALUES
low
normal
Adjust the lateral antenna
angle.
Adjust the vertical antenna
angle.
OR
RESETTING TO FACTORY VALUES:
4 m x 2 m (wide)
2 m x 2.5 m (narrow)
WIDTH
ANGLE
uni
AWAY
PRM &
AWAY
uni PRM = one-way detection also of people with reduced mobility
uni AWAY = one-way detection away from sensor
HOLD-OPEN TIME
MOUNTING
HEIGHT
DOOR CONTROL
0.5 s
1 s
2 s
3 s
4 s
5 s
6 s
7 s
8 s
9 s
< 3 m
> 3 m
auto
open
closed
open = the sensor detects constantly. The LED is ON.
closed = the sensor is in standby and does not detect. The LED is OFF.
2.2 m
2.2 m
high
> 2 seconds
2.2 m
2.2 m
highest