Configure the method with which the FCA and FCC outputs report the boom status.
Configuration
Functions
FCA FCC warnings
Disabled
Impulse
When the boom reaches the travel end (while opening or closing), the FCA-CM1 or
FCC-CM2 contact closes for one second.
Fixed
When the boom reaches the travel end (while opening or closing), the FCA-CM1 or
FCC-CM2 contact closes and remains closed.
Custom
The FCA-CM1 contact is closed with the boom in the open travel end position and
during the opening maneuver. The FCC-CM2 contact is closed with the boom in the
closed travel end position and during the closing maneuver.
Opening counter
With the function active, it is possible to send a series of opening commands corresponding to the number of vehicles which have to be authorized to pass through
the gate. The function can only be operated by control devices connected to the contact 2-3. The input to which the magnetic contact on which the loop that counts
the vehicles in transit is connected must be programmed to operate in C5/C9/C10 mode; at the end of the count the passage is closed.
Configuration
Functions
Opening counter
Deactivated (Default)
Activated
Boom drop-away detection
It activate the contact for detecting the boom drop-away.
Configuration >
Functions
Boom drop-away detection
Deactivated (default)
Activated
Show clock
Enables the clock displaying on the display.
The function is available only if the 806SA-0120 board is installed.
Timer management
Show clock
Confirm? NO
Confirm? YES
Set the clock
For setting date and time.
The function is available only if the 806SA-0120 board is installed.
Timer management
Set the clock
Use the arrows and the Enter button to enter the desired values.
Automatic DST
Enables the automatic summer time setting.
The function is available only if the 806SA-0120 board is installed.
Timer management
Automatic DST
Deactivated (Default)
Activated
RSE2
Configures the function to be performed by the board connected to the RSE2 connector.
Configuration
RSE communication
RSE2
Disabled
CRP (Default)
I/O module
RTU Modbus