Maintained action
With the function active, the operator movement (opening or closing) is interrupted when the control device is released.
Activation of the function excludes all other control devices.
Configuration >
Functions
Maintained action
Deactivated (Default)
Activated
Obst. with motor stopped
With the function active, the boom remains stopped if the safety devices detect an obstacle. The function activates with: closed rod, open rod or after a total stop.
Configuration >
Wired safety devices
Obst. with motor stopped
Deactivated (Default)
Activated
Open warning light
It warns of the state of the barrier.
Configuration >
Manage lights
Open warning light
Warning light on (Default) - The light stays on when the boom is moving or open.
Warning light flashing - The warning light flashes every half second when the boom is
opening and stays on when the boom is open. The light flashes every second when the
boom is closing and is off when the boom is closed.
Sensor type
It sets the type of control device.
Users management
Sensor type
Keypad
Transponder
Light E1
For choosing the type of device connected to the output.
Configuration >
Manage lights
Light E1
Flashing light (Default)
Cycle light
The light remains off if an automatic closing time is not set.
Automatic cls
It sets the time that must pass before the automatic closing is activated, once the opening travel end has been reached.
The function does not work if any of the safety devices trigger when an obstruction is detected, or after a total stop, or during a power outage.
Configuration >
Times
Automatic cls
Deactivated (Default)
from 1 to 180 seconds
Pre-flashing time
It sets the early activation time before each maneuvers.
Configuration >
Manage lights
Pre-flashing time
Deactivated (Default)
from 1 to 10 seconds
Opening speed
It sets the opening speed (percentage of maximum speed).
The percentage values automatically adapt to the value entered in the function [Boom length].
Configuration >
Gate travel settings
Opening speed
from 50% to 100% (Default 70%)
Closing speed
Sets the closing speed (percentage of maximum speed).
The percentage values automatically adapt to the value entered in the function [Boom length].
Configuration >
Gate travel settings
Closing speed
from 30% to 100% (Default 50%)