MASTER BARRIER
Send the ONLY OPEN command (contact 2-3)
from a transmitter or other control device, to
open the boom of the MASTER barrier.
Approach the SLAVE barrier. It will
automatically open only after the MASTER
barrier automatically closes. The automatic
closing of the MASTER barrier is excluded in
the event that the safety devices detect an
obstruction (such as when a car has yet to
clear the MASTER barrier).
SLAVE BARRIER
Send the PARTIAL/PEDESTRIAN OPENING
command (contact 2-3P) from a transmitter or
other control device, to open the boom on the
SLAVE barrier.
Approach the MASTER barrier. It will
automatically open only after the SALVE
barrier automatically closes. The automatic
closing of the SLAVE barrier is excluded in
the event that the safety devices detect an
obstruction (such as when a car has yet to
clear the SLAVE barrier).
EMERGENCY OPENING
Send the STEP-STEP (contact 2-7)
command from a transmitter or other
control device, to simultaneously open the
booms of the MASTER and SLAVE barrier.
Important! Before making any electrical connections and programming, do the following on both barriers:
- setting the boom type;
- motor test;
- calibrating the boom travel.
Fit the RSE card (with DIP switches sent to OFF) onto the control panel connector of both barriers.
Connect the two control panels via a CAT 5 type-cable (max 1,000 m) to terminals A-A / B-B / GND-GND, see paragraph on CONNECTING WITH
THE CAME REMOTE PROTOCOL (CRP) AND FOR PAIRED OR ALTERNATE OPERATING MODE.
Connect all of the control and safety devices to the MASTER control panel.
Important! Deactivate function F 19 (automatic closing time) on the SLAVE barrier's control panel.
Confi guring the MASTER barrier
Select function F 49. Press ENTER to confi rm.
Select 2 (alternate) and press ENTER.
Carry out any settings and adjustments on the MASTER control panel.
Transferring parameters from MASTER to SLAVE
Select function F 52 on the MASTER control panel.
Select 1 and press ENTER.
Operating modes
ONLY OPEN (contact 2-3) command. For opening MASTER barrier boom.
PARTIAL/PEDESTRIAN OPENING (contact 2-3P) command. For opening the SLAVE barrier boom.
STEP-STEP (contact 2-7) command. Both booms open. This is an emergency opening command, to free the passage.
For the types of command that can be selected and paired to users, see the ENTERING USERS WITH ASSOCIATED COMMANDS
ALTERNATE CONNECTION