Functions map
F 1
Total stop function (1-2)
F 2
Function associated to input CX
F 3
Function associated to input CY
F 5
Safety test function
F 6
Maintained action function
F 9
Obstruction detection with motor idle function
F 10
Warning light function
F 11
Encoder exclusion
F 14
Sensor type selection function
F 15
Intermittent luminous cord function
F 18
Additional light function
F 19
Automatic closing time
F 21
Preflashing time
F 22
Working time
F 25
Courtesy light time
F 28
Adjusting opening speed
F 29
Adjusting closing speed
F 30
Adjusting opening slow-down speed
F 31
Adjusting closing slow-down speed
F 33
Adjusting calibration speed
F 34
Sensitivity during movement
F 35
Sensitivity during slow-down
F 37
Adjusting the opening slow-down starting point
F 38
Adjusting the closing slow-down starting point
F 49
Enabling serial connections
F 50
Saving data in memory roll
F 51
Reading memory roll data
F 52
Copying parameters from Master to Slave
F 56
Number of the peripheral
F 60
Sleep Mode function
F 61
Pre-flashing function
F 63
Changing COM speed
U 1
Type of command to associate to a user via radio control
U 2
Deleting single users
U 3
Deleting all users
A 1
Boom-type setting
A 2
Motor test
A 3
Calibrating boom travel
A 4
Resetting parameters
A 5
counting the number of maneuvers
H 1
Software version
Functions menu
F1
Total stop [1-2]
0 = Deactivated (
default
) / 1 = Activated
NC input - boom stop while excluding any automatic stop; to resume movement, use a control device. Connect the safety device to 1-2.
F2 Input
[2-CX]
0 = Deactivated (
default
) / 1 = C1 / 4 = C4 / 5 = C5 / 9 = C9
NC Input - For associating: C1 = reopening during closing for photocells, C4 = obstruction wait, C5 = immediate closing, C9 = immediate
closing with obstruction wait when closing.
F3 Input
[2-CY]
0 = Deactivated (
default
) / 1 = C1 / 4 = C4 / 5 = C5 / 9 = C9
NC Input - For associating: C1 = reopening during closing for photocells, C4 = obstruction wait, C5 = immediate closing, C9 = immediate
closing with obstruction wait when closing.
IMPORTANT! Start programming by first performing the following: A1 BOOM-TYPE SETTING, A2 MOTOR TEST,
F1 TOTAL STOP and A3 CALIBRATING BOOM TRAVEL.