background image

P.

 

33

 - 

M

an

u

al

 c

od

e: 

11

9

A

V

7

0

11

9

A

V

7

0

 ve

r.

 

1

.1

1.

1

 08

/2

0

11

 © C

A

M

E c

an

ce

lli

 auto

m

ati

ci

 s.p.a. - T

h

e d

ata a

n

d i

nf

or

m

ati

on i

n th

is

 m

an

u

al

 m

ay b

e c

h

an

g

ed at a

ny ti

m

e a

n

d w

ith

ou

t o

b

lig

ati

on

 o

n th

e p

art of C

am

e C

an

ce

lli

 A

uto

m

ati

ci

 S

.p.a. to n

otify s

ai

d c

h

an

g

es.

ENGLISH

WARNING!

Important instructions for the safety of people: 

READ CAREFULLY!

Foreword

• Use of the products must be restricted to its intended use 
(i.e. that for which it was expressly built for). Any other use is 
to be considered dangerous. Came Cancelli Automatici S.p.A. 
is not liable for any damage resulting from improper, wrongful 
or unreasonable use •  Keep these warnings with the installa-
tion and use manuals issued with the automated system.

Before installing 

(preliminary check: in case of a negative 

outcome, do not proceed before having 

complied with the safety obligations)

• Make sure that the parts you intend to automate are in 
good working order, and that they are  properly balanced 
and  aligned.  Also,  make  sure  that  proper  mechanical  stops 
are already in place • If the operator will be installed at a 
height  of  less  than  2.5  m  from  the  ground  or  other  access 
level, check whether you will need any protections and/or 
warnings • Any gate leaves, fi tted with pedestrian entrances, 
onto which you will install an operator, must have a blocking 
mechanism when the gate is in motion • Make sure that the 
opening of the automated gate is not an entrapment hazard 
as regards any surrounding fi xed parts • Do not mount the 
operator  upside  down  or  onto  any  elements  that  may  fold 
under its weight. If needed, add suitable reinforcements at 
the points where it is secured • Do not install onto gates on 
either an upward or downward slope (i.e. that are not on fl at, 
level ground) • Check that any lawn watering devices will not 
wet the gearmotor from the bottom up.

Installation

• Carefully section off the entire site to prevent unauthorised  
access, especially by minors and children • Be careful when 
handling operators that weigh more than 20 Kg (see installa-
tion manual). In such cases, employ proper weight handling 
safety equipment • All opening commands (e.g. buttons, key 
selectors, magnetic detectors, etc.) must be installed at least 
1.85 m from the gate’s area of operation perimeter - or where 
they cannot be reached from the outside of the gate. Also, 
the direct commands (e.g. push button, or proximity devices, 
etc.) must be installed at a height of at least 1.5 m and must 
not be accessible to the public • All ‘maintained action’ com-
mands, must be placed where the moving gate leaves, transit 
areas and driveways are completely visible • If missing, ap-
ply a permanent label that shows the position of the release 
mechanism • Before delivering to the client, verify that the 
system is EN 12453 (impact test) standard compliant. Make 
sure that the operator has been properly adjusted and that the 
safety and protection devices, as well as the manual release 

are working properly • Where necessary and in plain sight, 
apply the Warning Sings (e.g. gate plate).

Special instructions and 

advice for users

• Keep the gate’s area of operation clean and clear of any 
obstacles. Trim any vegetation that may interfere with the 
photocells • Do not allow children to play with the fi xed com-
mand  devices,  or  in  the  gate’s  area  of  operation.  Keep  any 
remote control devices (i.e. transmitters) away from the chil-
dren as well • Frequently check the system, to see whether 
any anomalies or signs of wear and tear appear on the moving 
parts, on the component parts, on the securing points, on the 
cables and any accessible connections. Keep any joints (i.e. 
hinges)  lubricated and clean, and do the same where fric-
tion may occur (i.e. slide rails) • Perform functional tests on 
photocells and sensitive edges, every six months. Keep glass 
panels constantly clean (use a slightly water-moistened cloth; 
do not use solvents or any other chemical products) • If the 
system requires repairs or modifi cations, release the operator 
and do not use it until safety conditions have been restored 
• Cut off the power supply before releasing the operator for 
manual openings. See instructions • Users are FORBIDDEN 
to carry out ANY ACTIONS THAT THEY HAVE NOT BEEN 
EXPRESSLY ASKED TO DO OR SO INDICATED in the manu-
als. Any repairs, modifi cations to the settings and extraor-
dinary maintenance MUST BE DONE BY THE TECHNICAL 
ASSISTANCE STAFF • On the periodic maintenance log, note 
down the checks you have done.

Special instructions and 

advice for all

• Avoid working near the hinges or moving mechanical parts 
• Stay clear of the gate’s area of operation when in motion • 
Do not resist the direction of movement of the gate; this may 
present a safety hazard • At all times be extremely careful 
about dangerous points that must be indicated by proper 
pictograms and/or black and yellow stripes • When using 
a selector or command in ‘maintained action’ mode, keep 
checking that there are no people in the area of operation of 
the moving parts. Do this until you release the command • 
The gate may move at any time without warning • Always cut 
the power when cleaning performing maintenance. 

Содержание FROG PLUS Series

Страница 1: ...SERIES FROG PLUS INSTALLATION MANUAL FROG PM BELOW SURFACE SWING GATE OPERATOR English EN...

Страница 2: ...tallation P 5 Preliminary checks P 5 Tools and equipment P 6 Types and thicknesses of cables P 6 Standard installation P 6 Preparing the foundation box P 7 Installing the operator P 8 Connecting to th...

Страница 3: ...to the public All maintained action com mands must be placed where the moving gate leaves transit areas and driveways are completely visible If missing ap ply a permanent label that shows the positio...

Страница 4: ...C 50 60 Hz 230V AC 50 60 Hz Motor power supply 230 V AC 50 60 Hz 230 V AC 50 60 Hz Maximum draw 5 1 A 2 6 A Power rating 1200 W 600W Maximum Torque 800 N 800 N Opening time 90 30 S 45 S Reduction rati...

Страница 5: ...following is necessary Set up a suitable omnipolar cut off device with distances greater than 3 mm between contacts wit sectioned power source Set up proper conduits and electric cable raceways making...

Страница 6: ...TWISTED 3 x 0 5 mm2 Connecting the antenna RG58 max 10 m N B If cables are of a different length than that shown in the table determine the cable section based on the actual draw and the number of con...

Страница 7: ...ends on the dimensions It is up to the installer to choose the most suited solution Dig a pit to house the box set up junction boxes with the corrugated tubes required to thread connections coming fro...

Страница 8: ...Cancelli Automatici S p a to notify said changes ENGLISH Installing the operator Lubricate the foundation box pin the anchoring lever and gate bracket pin N B orientation of illustration right hand in...

Страница 9: ...the gate leaf to ease mounting of the gearmotor Insert the gearmotor into the box fasten it via the threaded pins and lock it using the supplied screws Insert the adjusting screw into the motor arm H...

Страница 10: ...LISH 1 Control panel 2 Left gear motor 3 Right gearmotor 4 Junction box 5 Junction pit Connecting the 230 V A C gearmotor with opening delay Connecting the 230 V A C gearmotor with closing delay 230 V...

Страница 11: ...0 N B orientatation of illustration right hand inside view Turn the adjusting screw 1 of the motor arm 3 Open the gate leaf until it touches the opening strike plate loosesn the adjusting screw 1 unti...

Страница 12: ...tion box and fasten it using the screws N B orientatation of illustration right hand inside view M8x25 UNI 5933 screw The manual release lets the gate leaves open and then re attach to close in case o...

Страница 13: ...y be changed at any time and without obligation on the part of Came Cancelli Automatici S p a to notify said changes ENGLISH Insert the key into the manual release lock and turn it counter clockwise O...

Страница 14: ...y mistake Immediately stop using the operator if any anomaly is manifested Danger of hand crushing Danger of foot crushing Danger high voltage Transit forbidden during operation The periodic maintenan...

Страница 15: ...opens nor closes No power supply The gearmotor is released The tramitter battery is run down The tramsitter is out of order The stop button is stuck or broken The opening closing button or key switch...

Страница 16: ...Job carried out _______________________________________________________________________________________ _______________________________________________________________________________________________...

Страница 17: ...70 ver 1 1 1 1 08 2011 CAME cancelli automatici s p a The data and information in this manual may be changed at any time and without obligation on the part of Came Cancelli Automatici S p a to notify...

Страница 18: ...Automation Solutions Pvt Ltd Automation Solutions Pvt Ltd A 10 Green Park 110016 New Delhi New Delhi 91 11 64640255 256 91 2678 3510 CAME Americas Automation Llc CAME Americas Automation Llc U S A 11...

Отзывы: