Page
20
- Manual
FA01047-EN
- 08/2018 - © C
AME S.p.A. - Original instructions
F23
Delay in opening time
After an opening command, the M1 gearmotor starts delayed. The delay time is settable between
one and ten seconds.
0
= Deactivated /.../
2
= 2 seconds (
default
) /.../
10
= 10 seconds
F24
Closing delay time
After either a closing command or an automatic closing, the M2 gearmotor starts delayed. The
delay time is adjustable between one and five seconds.
0
= Deactivated /.../
5
= 5 seconds (
default
) /.../
25
= 25 seconds
F26
Closing thrust time
After an opening or closing command, the gearmotor thrusts inward for an adjustable time
between one and two seconds.
1
= 1 second (
default
) /
2
= 2 seconds
F27
Lock time
After an opening or closing command, the electric lock releases for an adjustable time between
one and four seconds.
1
= 1 second (
default
) /.../
4
= 4 seconds
F28
Gate travel speed
Setting the gate's opening and closing speeds, calculated as a percentage.
60
= 60% of the maximum speed /…/
100
= 100% of the maximum speed (
default
)
For FA7024CB gearmotors, the minimum speed is 50.
F30
Slow-down speed
Setting the gate's opening and closing slow-down speed, calculated as a percentage.
10
= 10% of the maximum speed /…/
50
= 50% of the maximum speed (
default
) /.../
60
=
60% of the maximum speed
For FA7024CB gearmotors, the minimum speed is 30.
F33
Calibration speed
Setting the gearmotors' speeds during calibration, calculated as a percentage.
20
= 20% of the maximum speed /… /
50
= 50% of the maximum speed (
default
) /.../
60
=
60% of the maximum speed
F34
Travel sensitivity
Adjusting obstruction detection sensitivity during gate travel.
10
= Maximum sensitivity /…/
100
= Minimum sensitivity (
default
)
F35
Slow-down sensitivity
Adjusting obstruction detection sensitivity during slow-down.
10
= Maximum sensitivity /…/
100
= Minimum sensitivity (
default
)
F36
Adjusting the partial
opening
Adjustment as a percentage of total travel, during gate opening.
10
= 10% of the travel /…/
40
= 40% of the travel (
default
) /... /
80
= 80% of the travel
F37
Opening slow-down
point for the M1 motor
Adjustment as a percentage of total travel, of the beginning slow-down point of gearmotor M1
during opening.
This function only appears if the Encoder function is activated.
1
= 1% of the travel /…/
25
= 25% of the travel (
default
) /…/
60
= 60% of the travel
F38
Closing slow-down
point of the M1 motor
Adjustment as a percentage of total travel, of the beginning slow-down point of gearmotor M1
during closing.
This function only appears if the Encoder function is activated.
1
= 1% of the travel /…/
25
= 25% of the travel (
default
) /…/
60
= 60% of the travel
F39
Opening approach
point of the M1 motor
Adjusting as a percentage of the total travel, the gearmotor M1 opening approach starting point.
This function only appears if the Encoder function is activated.
1
= 1% of the travel /…/
10
= 10% of the travel (
default
)
F40
Closing approach
point for motor M1
Adjusting as a percentage of the total travel, the gearmotor M1 closing approach starting point.
This function only appears if the Encoder function is activated.
1
= 1% of the travel /…/
10
= 10% of the travel (
default
)
F41
Opening slow-down
point for the M2 motor
Adjustment as a percentage of total travel, of the beginning slow-down point of gearmotor M2
during opening.
This function
only appears
if the Encoder function is activated.
1
= 1% of the travel /…/
25
= 25% of the travel (
default
) /…/
60
= 60% of the travel
F42
Closing slow-down
point of the M2 motor
Adjustment as a percentage of total travel, of the beginning slow-down point of gearmotor M2
during closing.
This function
only appears
if the Encoder function is activated.
1
= 1% of the travel /…/
25
= 25% of the travel (
default
) /…/
60
= 60% of the travel
Содержание FA7024CB
Страница 2: ...2 3 1 2 3 1 ...
Страница 31: ......
Страница 33: ...Swing gate operator FA7024CB FST23DLC INSTALLATION MANUAL EN English FA01047 EN ...
Страница 34: ...2 3 1 2 3 1 ...
Страница 63: ......
Страница 65: ...Automatismes pour portails battants FA7024CB FST23DLC MANUEL D INSTALLATION FR Français FA01047 FR ...
Страница 66: ...2 3 1 2 3 1 ...
Страница 95: ......
Страница 97: ...Автоматика для распашных ворот FA7024CB FST23DLC РУКОВОДСТВО ПО МОНТАЖУ RU Русский FA01047 RU ...
Страница 98: ...2 3 1 2 3 1 ...
Страница 127: ......