7) Adjust the cable tension on the mechanism by
means of the adjustment screw and verify that the
NC contact micro switch operates properly
with an Ohmmeter.
Important: for proper adjustment, make
sure the mechanism starts up after 20 mm
max. deformation.
Secure the screw to block the mechanism.
1
2
3
5) Insert the micro switch holder mechanism.
Once inserted, release the lever with slight downward pressure and
tighten the two UNI6955 ø 2.9x13 screws
2
1
3
4
6) Insert the steel cable in the connecting terminal hole; insert
everything in the lever, tension the cable and screw.
Once the cable is adjusted, cut any excess cable.
1
20 mm
3
2
1) Pre-stop = 20 mm
2) Intervention point, response time = 0.2 s
3) Overstop = 45 mm
4) Recovery time at initial point = 2 s
1
2
3
4