P
age
16
- Manual
FA01509-EN
- 05/2021 - © C
AME S.p.A. - The contents of this manual may be changed at any time and without notice. - T
ranslation of the o
riginal instructions
Power supply
Make sure the mains power supply is disconnected during all installation procedures.
Before working on the control panel, disconnect the mains power supply and remove the batteries, if any.
Connecting to the mains (230/120 V AC - 50/60 Hz)
F
Line fuse
L
Phase
N
Neutral
Earth
E
Ferrite
Apply the ferrite supplied to the power supply cable.
Ferrite type p.n. ECQK922091.
The cable must pass through the ferrite twice (2 turns).
F
E
230 V AC
Power supply output for accessories
The output normally delivers 24 V AC.
The sum of the power draw for the connected
accessories must not exceed 40 W.
10 11 E 5
24 0
E 5
24 0
Maximum capacity of contacts
Device
Output
Power supply (V)
Power (W)
Accessories
10 - 11
24 AC
20
Additional light
10 - E
24 AC
25
Flashing beacon
10 - E
24 AC
25
The outputs deliver 24 V DC when the batteries start operating, if they are installed.