P
age
20
- Manual
FA01509-EN
- 05/2021 - © C
AME S.p.A. - The contents of this manual may be changed at any time and without notice. - T
ranslation of the o
riginal instructions
PROGRAMMING
Programming button functions
1
ESC button
The ESC button is used to perform the operations described below.
Exit the menu
Delete the changes
Go back to the previous screen
Stop the operator
2
< > buttons
The <> buttons are used to perform the operations described below.
Navigate the menu
Increase or decrease values
< Use this button to close the gate
> Use this button to open the gate
3
ENTER button
The ENTER button is used to perform the operations described below.
Access menus
Confirm choice
Getting started
Once the electrical connections have been made, proceed with commissioning. Only skilled and qualified staff may perform this operation.
Make sure that there are no obstacles in the way.
Power up the device and begin programming.
Start programming with the functions indicated below.
F54
Opening direction
Set the gate opening direction.
F1
Total stop
Stop the gate and exclude automatic closing. Use a control device to resume
movement.
A3
Travel calibration
Start the travel self-learning.
After powering up the system, the first manoeuvre is always to open the gate Wait for the manoeuvre to be completed.
Press the ESC button or STOP button immediately in the event of any faults, malfunctions, strange noises or vibrations, or unexpected behaviour in the
system.
If the three display segments are flashing, calibrate the travel.
Functions menu
Total stop
Stop the gate and exclude automatic closing. Use a control device to resume movement.
F1
Total stop
OFF (Default)
ON