background image

L1T

L2T

L1T

L2T

24V

0V

EbA

EbA

EbI
EbI

10
11
 1

2
3

4
EM

2
S1
S2

Pa

g

9

  - M

an

u

al

 c

od

e: 

11

9

G

3

7

8

4

E

N

11

9

G

3

7

8

4

E

N

 ve

r.

 

2

  

2  

0

2

/2

0

14  © C

A

M

E

 c

an

ce

lli

 auto

m

ati

ci

 S

.p.

A

. - T

h

e d

ata a

n

d i

n

fo

rm

ati

on p

rovi

d

ed

 in

 th

is

 m

an

u

al

 a

re s

u

b

je

ct to c

h

an

g

e at a

ny ti

m

e w

ith

ou

t p

ri

or n

oti

ce

 by C

A

M

E

 C

an

ce

lli

 A

u

to

m

ati

ci

 S

.p.a.

White

Red (230 V AC)

White

Black (120 V AC)

Blue
Blue

Transformer

Red
Red

Red
Red

Electric lock

Devices to be connected 

PSAP08

PSAP08

Direction arrows  

Control devices 

PSAP08

PSAP08

PSAP07N

PSAP07N

Stop button

 (N.C. contact).

Blocks the turnstile.

Anti-clockwise operation button

 

(N.O. contact).

Allows anti-clockwise unlocking of the tripod.
The tripod will lock automatically after a fi xed time of 10 s.

Clockwise operation button

 

(N.O. contact).

Allows clockwise unlocking of tripod.
The tripod will lock automatically after a fi xed time of 10 s.

Release button

 (N.C. contact).

Allows to tripod to be unlocked for rotation in both directions.

Terminal block for

 24 V AC powering of accessories with maxi-

mum current and power draw of 500 mA and 35 W respectively. 

 

 Wait 10 seconds before performing any operation after connecting the turnstile to the electrical mains.

Содержание BRIDGE PSAP01

Страница 1: ...INSTALLATION MANUAL English EN TRIPOD TURNSTILES BRIDGE PSAP01 PSAP07N PSAP08 119G3784EN...

Страница 2: ...1 5 m and must not be accessible to the public The turnstile identi cation data must be clearly visible Before connecting the turnstile to the power supply make sure the identi cation data correspond...

Страница 3: ...pod release in the event of a blackout 001PSAP08 Two way mechanical turnstile in galvanised painted steel RAL 7035 complete with control board hydraulic damper and LED direction arrows Automatic tripo...

Страница 4: ...tal casing 4 Housing 5 Top cover 6 Mechanism 7 TOR100A control panel 8 Cover lock 9 Screws and washers for fixing the legs to the casing Dimensions Example of a system 1 Tripod turnstile 2 Direction a...

Страница 5: ...o the actual current draw of the devices connected and according to the provisions of the IEC EN 60204 1 standard For connections that require several sequential loads the sizes given on the table mus...

Страница 6: ...turnstile Open the lock using the key lift the cover and slightly pull it forward while pulling it upwards Lift the casings and remove them Attach the arms to the head of the tripod with screws M10x60...

Страница 7: ...d Once you have determined the location use a pencil to mark the drill holes according to the dimensions indicated mm Place the turnstile over the wall dowels If present the corrugated conduit for the...

Страница 8: ...e cables and Ref Description L1T White L2T Red Black isolated Ref Description L1T White Red isolated L2T Black Replace the 1 6A line fuse with a 3 15 A unit Operations reserved for the installing tech...

Страница 9: ...08 PSAP07N PSAP07N Stop button N C contact Blocks the turnstile Anti clockwise operation button N O contact Allows anti clockwise unlocking of the tripod The tripod will lock automatically after a xed...

Страница 10: ...t be taken into account to properly adjust the hydraulic damper Remove line voltage during installation and make sure that the tripod moves freely Loosen the nut Acting on the tripod perform simulated...

Страница 11: ...rvice Restore the spring Check the contact The turnstile remains locked The free direction cam is incorrectly positioned or damaged The person going through leaned on the arm before it was released Bo...

Страница 12: ...nd other relevant provisions established in Directives 2006 95 EC and 2004 108 EC A true copy of the declaration of conformity is available upon request DISMANTLING AND DISPOSAL CAME CANCELLI AUTOMATI...