Emergency button

CAUTION!

important personal safety instructions:

READ CAREFULLY!

Foreword

• This product should only be used for the purpose for which it was explicitly
designed. Any other use is considered dangerous. CAME Cancelli Automatici
S.p.A. will not be held liable for damage caused by improper, incorrect or
unreasonable use. • The safety of the product, and therefore its proper
installation, depends on total compliance with the technical specifi cations and
installation procedures, as well as with rules regarding safety and use, expressly 
mentioned in the technical documentation for the products themselves. • Keep
these warnings together with the installation and operation manuals for the
operator system components.

Before installing

(preliminary check: in case of a negative outcome, do not proceed until you 
have complied with the safety requirements)

• Installation and testing must only be performed by qualifi ed personnel •
Cable routing, installation, connection and testing must be carried out to
the highest levels of workmanship in accordance with applicable laws and
regulations • Before starting any operation, read all the instructions carefully;
incorrect installation can be dangerous and harm persons or property • Check
that the operator is in good mechanical condition, balanced and aligned, and
that it opens and closes properly. If needed, also install suitable guards or use
appropriate additional safety sensors • If the operator will be installed at a
height of less than 2.5 m from the ground or other access level, check whether
you will need any protections and/or warnings • Ensure that opening the
turnstile does not create a dangerous situation • Do not mount the operator
upside down or onto any elements that may fold under its weight. If needed,
add suitable reinforcements at the points where it is secured • Do not install on 
ground that is not level • Check that any lawn watering devices will not wet the 
operator from the bottom up.

Installation

• Carefully section off  the entire site to prevent unauthorised access, especially 
by minors and children • Be careful when handling operators that weigh more
than 20 kg. In such cases, use proper weight handling safety equipment •
CE safety devices (photocells, platforms, sensitive edges, emergency button
etc.) must be installed in compliance with applicable legislation and according
to the highest standards of workmanship, bearing in mind the environment,
the type of service required and the operating forces applied to the moving
turnstiles. Points where there is a risk of crushing, shearing or dragging must be 
protected using suitable sensors • End users must be informed of any residual
risks by means of special pictograms as envisaged by legislation • All opening
commands (buttons, key selectors, magnetic readers etc.) must be installed at
least 1.85 m from the perimeter of the area of turnstile movement, or where
they cannot be reached from outside through the turnstile. Also, the direct
commands (buttons, touch commands etc.) must be installed at a height of at
least 1.5 m and must not be accessible to the public • The turnstile identifi cation 
data must be clearly visible • Before connecting the turnstile to the power
supply, make sure the identifi cation data corresponds to the mains data • The
turnstile must be connected to an eff ective, compliant earthing system.  • All
‘maintained actions’ commands must be placed where the moving turnstile and 
transit/manoeuvre areas are clearly visible • Before delivery to the user, check
that the system complies with the EN 12453 and EN 12445 standards (impact
tests), check that the operator has been properly adjusted and that the safety
and protective devices work correctly • Apply Warning Symbols where needed
and in clearly visible areas.

Special instructions and advice for users

• Keep the turnstile’s area of operation clean and clear of any obstacles. Check
that the photocells' area of operation is free from obstacles • Children must be
supervised to make sure they do not play with the operator and the fi xed control 
devices or stand in the turnstile's area of operation. Keep any remote control
devices (i.e. transmitters) or any control devices away from children as well,
to prevent the operator from being activated accidentally • The operator is not
designed to be used by persons (including children) whose physical, sensorial
or mental capacities are limited, or who are lacking in experience or knowledge, 
unless said persons can be supervised or given instructions regarding using the 
operator by a person responsible for their safety • Frequently check the system, 

to see whether any anomalies or signs of wear and tear appear on the moving 
parts, on the component parts, on the securing points, on the cables and any 
accessible connections. Keep any joints lubricated and clean, and do the same 
where friction may occur • Perform functional tests on photocells every six 
months. Ensure that the glass on the photocells is kept clean (use a cloth slightly 
moistened with water; do not use solvents or any other chemicals as these 
could damage the devices) • If the system requires repairs or modifi cations, 
disconnect the power to the operator and do not use it until safety conditions 
have been restored • Cut off  the electrical power supply for manual opening. 
Read the instructions • If the power cable is damaged, it must be replaced 
by the manufacturer or the technical assistance service or by a person with a 
similar qualifi cation so as to prevent any risks • It is STRICTLY FORBIDDEN for 
users to perform OPERATIONS THEY ARE NOT EXPLICITLY REQUIRED AND ASKED 
to do. For repairs, adjustments and extraordinary maintenance, CONTACT THE 
SPECIALIST TECHNICAL SERVICE CENTRE • On the periodic maintenance log, 
note down the checks you have done.

Further special instructions and advice for all

• Avoid working near the turnstiles or moving mechanical parts • Stay clear of
the turnstile's area of operation when in motion • Do not resist the direction
of movement of the operator; this may present a safety hazard • At all times
be extremely careful about dangerous points that must be indicated by
proper pictograms and/or black and yellow stripes • When using a selector or
command in ‘hold-to-run’ mode, keep checking that there are no people in the
area of operation of the moving parts. Do this until you release the command
• The turnstile may move at any time without warning • Always cut the power
when cleaning or performing maintenance.

Danger of hand crushing

Danger - live parts

No transit during the manoeuvre

Содержание BRIDGE PSAP01

Страница 1: ...INSTALLATION MANUAL English EN TRIPOD TURNSTILES BRIDGE PSAP01 PSAP07N PSAP08 119G3784EN...

Страница 2: ...1 5 m and must not be accessible to the public The turnstile identi cation data must be clearly visible Before connecting the turnstile to the power supply make sure the identi cation data correspond...

Страница 3: ...pod release in the event of a blackout 001PSAP08 Two way mechanical turnstile in galvanised painted steel RAL 7035 complete with control board hydraulic damper and LED direction arrows Automatic tripo...

Страница 4: ...tal casing 4 Housing 5 Top cover 6 Mechanism 7 TOR100A control panel 8 Cover lock 9 Screws and washers for fixing the legs to the casing Dimensions Example of a system 1 Tripod turnstile 2 Direction a...

Страница 5: ...o the actual current draw of the devices connected and according to the provisions of the IEC EN 60204 1 standard For connections that require several sequential loads the sizes given on the table mus...

Страница 6: ...turnstile Open the lock using the key lift the cover and slightly pull it forward while pulling it upwards Lift the casings and remove them Attach the arms to the head of the tripod with screws M10x60...

Страница 7: ...d Once you have determined the location use a pencil to mark the drill holes according to the dimensions indicated mm Place the turnstile over the wall dowels If present the corrugated conduit for the...

Страница 8: ...e cables and Ref Description L1T White L2T Red Black isolated Ref Description L1T White Red isolated L2T Black Replace the 1 6A line fuse with a 3 15 A unit Operations reserved for the installing tech...

Страница 9: ...08 PSAP07N PSAP07N Stop button N C contact Blocks the turnstile Anti clockwise operation button N O contact Allows anti clockwise unlocking of the tripod The tripod will lock automatically after a xed...

Страница 10: ...t be taken into account to properly adjust the hydraulic damper Remove line voltage during installation and make sure that the tripod moves freely Loosen the nut Acting on the tripod perform simulated...

Страница 11: ...rvice Restore the spring Check the contact The turnstile remains locked The free direction cam is incorrectly positioned or damaged The person going through leaned on the arm before it was released Bo...

Страница 12: ...nd other relevant provisions established in Directives 2006 95 EC and 2004 108 EC A true copy of the declaration of conformity is available upon request DISMANTLING AND DISPOSAL CAME CANCELLI AUTOMATI...