background image

14 

optional ACCESSORIES

For more kit accessories please contact 

Sales

 on 

0115 9210 430

Code(s)

Description

RADIO KEYPAD SELECTORS

806SL-0170

SELT1W4G - Surface-mounted, 433.92 MHz radio-frequency keypad selector, 12-keys, with blue backlighting. 25 savable 

codes and password to access the programming mode. Settable in Rolling Code or Fixed Code mode. RAL7024 Grey colour.

806SL-0180

SELT1W8G - Surface-mounted, 868.35 MHz radio-frequency keypad selector, 12-keys, with blue backlighting. 25 savable 

codes and password to access the programming mode. Settable in Rolling Code or Fixed Code mode. RAL7024 Grey colour.

001

AF868

Plug-in 868.35 MHz radio frequency control card.

Required for 806SL-0180.

BLUETOOTH SELECTORS

806SL-0210

SELB1SDG1 - Surface-mounted with blue backlighting, for 15 users. RAL7024 Grey colour.

806SL-0240

SELB1SDG2 - Surface-mounted with blue backlighting, for 50 users. RAL7024 Grey colour.

806SL-0250

SELB1SDG3 - Surface-mounted with blue backlighting, for 250 users. RAL7024 Grey colour.

TRANSPONDER SELECTORS

806SL-0300

SELR1BDG - Surface-mounted Bus transponder reader for cards, keyfobs and TAG (Manchester protocol) with blue 

backlighting. RAL7024 Grey colour.

806SL-0310

SELR2BDG - Flush-mounted Bus transponder reader for cards, keyfobs and TAG (Manchester protocol) with blue 

backlighting. RAL7024 Grey colour.

001

R700

Programming board and access control management when used with transponder.

Required for 806SL-0300 and 806SL-0310.

HARDWIRED KEYPAD SELECTORS

 

806SL-0280

SELT1BDG - Surface-mounted 12 button Bus keypad with blue backlighting. 

RAL7024 Grey colour. 

 

806SL-0290

SELT2BDG - Flush-mounted 12 button Bus keypad with blue backlighting. 

RAL7024 Grey colour.  

 

001

R800

Control board for programming and access-control management via keypad selectors. 

Required for 806SL-0280 and 806SL-0290.

TOP - ROLLING CODE

8K06TS-001

TOPD4RXM - 6 packaged dual frequency 4 button rolling code transmitters. 

4,294,967,896 combinations.

PHOTOCELLS

  

Surface mounted. Synchronised beam, multiple pairs of photocells can be applied to the same system,  

even at double height and/or close to each other - with no interference issues (cross talk).

001

DIR10

Pair of 12 - 24 V AC - DC outdoor photocells - range 10m.

001

DIR20

Pair of 12 - 24 V AC - DC outdoor photocells - range 20m.

001

DIR30

Pair of 12 - 24 V AC - DC outdoor photocells - range 30m.

PHOTOCELL column

001

DIRL

Natural finish aluminium post. H = 500mm

001

DIRLN

Black anodised aluminium post. H = 500mm

001

DIRCG

Silver RAL9006, PVC post. H = 500mm

CAME KEY

806SA-0110

WiFi internet gateway. Communicate directly with your smartphone or tablet, allowing you to manage the configuration of 

your device with no need for an internet connection.

Содержание BKV1500P

Страница 1: ...CAME COM UK BKV1500P kit Complete kit for a sliding gate weighing up to 1500kg max width 20m QUICK SETUP GUIDE TO BE READ IN CONJUNCTION WITH THE FULL INSTRUCTION MANUAL...

Страница 2: ...er RGSM001S Gateway Module RSE Connection Card SIM May be preinstalled in RGSM001S 1 Kit Contents 2 Safety Instructions 3 Typical Gate Setup 4 Geometry 5 Manual Release Instructions 6 Wiring Diagram 7...

Страница 3: ...ssing through the gate Keep feet away from the bottom of the gate during operation Do not operate the gate by remote control unless they are in view Do not attempt to block or interfere with the gate...

Страница 4: ...5 3 4 6 OUTSIDE OF GATES INSIDE OF GATES 10 11 12 8 1 BKV Motor 5 Selector Keypad optional 9 Photocell column optional accessory 2 Limit switch fins 6 Photocells on outside of gate posts 10 Slide guid...

Страница 5: ...to the accessories 5 Prepare a 20 mm tube to run the release cord through A 6 Use 40 mm corrugated tubes to connect the gearmotor to the accessories The number of tubes depends on the type of system a...

Страница 6: ...y 4 Attempt to manually open the gate to ensure the system is fully engaged The BKV sliding gate operator has a manual release system found behind a locked compartment on the front of the motor Basic...

Страница 7: ...e length RX 4 Core 0 5mm Flex TX 4 Core 0 5mm Flex 1m 30m Mains Supply 230 V AC Cable length 1m 20m 3 Core 1 5mm Flex 20m 30m 3 Core 2 5mm Flex AF43S Plug in 1 2 3P 7 10 TS 2 CX CY M N FC FA F E L N A...

Страница 8: ...ength or availability and therefore will not be held liable for lack of service came automation internet came cloud setup app for the installer GET IT ON AppStore GET IT ON automation app for the end...

Страница 9: ...indicating the RGSM001S is registered on a GSM network 2 POWER LED Green The LED will flash 5x sec indicating the RGSM001S is not yet configured on the Connect platform Power on the control board The...

Страница 10: ...rrive please check your junk folder download the connect setup app adding the rgsm gateway to your technician account technician connect setup app 1 3 2 If you have an existing account please move to...

Страница 11: ...Bm 24V CONNECT 123 4 GND A N T 10 2 COM IN2 COM IN1 B A 1A 30V RGSM001S If you intend to retain control of the SIM for top up If as the installer you intend to retain control of the SIM for top up pur...

Страница 12: ...utomation Select Manual Add Select BKV ZN8 from the drop down list Enter a name and description then press Add adding automation 1 BKV ZN8 Automation for sliding gates BKV1500 Front Gates Front Gates...

Страница 13: ...Select Add Select either Local Acquisition or Add with QR Code If you pressed Local Acquisition the screen will change to the one shown here Select the button on the fob and it will add the button str...

Страница 14: ...cess for all fobs Select the back button to return to the main menu If you select ADD via QR Code the app will open the devices camera enabling scanning of the QR code on the fobs packaging Once the Q...

Страница 15: ...n App On first login you will be prompted to accept the gateway You will then be presented with control options for your automation To transfer to a customer select the 3 dots Select Transfer site Ent...

Страница 16: ...tem mode Single Opening direction To the left or To the right As viewed from the inside of the property looking outwards CX input Disable CY input Disable CZ input Disable CK input Disable Travel AST...

Страница 17: ...ing will be displayed Repeat the same procedure for adding another button A maximum of 250 individual buttons can be saved remove a transmitter button 1 Press hold button Configuration is displayed 2...

Страница 18: ...automation is in either its opening or closing cycle and the safety circuit is triggered the automation will stop Once the safety is no longer triggered the automation will carry on the cycle it was...

Страница 19: ...waiting another activation from a command device R8 Reclosing during opening sensitive edges with 8K2 resistor Direct connection of an 8k2 resistive edge When the automation is in its opening cycle an...

Страница 20: ...and fit the replacement SIM card into the slot Replace the casing and power up the control panel Send an SMS to the telephone number of the SIM reporting the APN details Access Point Name ask the serv...

Страница 21: ...for cards keyfobs and TAG Manchester protocol with blue backlighting RAL7024 Grey colour 001R700 Programming board and access control management when used with transponder Required for 806SL 0300 and...

Страница 22: ...correct use of the Software requires the possession of an automation home automation security temperature control and or video surveillance system manufactured by Came which has been enabled for remo...

Страница 23: ...ation of the automation home automation security temperature control and or video surveillance system manufactured by Came may be associated with the system itself In this way the installer can perfor...

Страница 24: ...immediate effect in the event of the violation of the terms of Articles 2 2 and or 2 5 In this case termination shall occur automatically upon receipt by the Installer of the notification sent by Came...

Страница 25: ...vidual parts of the additional network services and other related services referred to in Section 3 1 lit c of these GTC 1NCE expressly points out that the type and scope of such services of the respe...

Страница 26: ...tion 2 of these GTC for the Services Within the framework of the conclusion of the contract the Customer may choose between different payment methods offered by 1NCE Unless otherwise agreed between th...

Страница 27: ...a Protection Act Bundesdatenschutzgesetz 10 2The Parties also undertake to treat all other confidential information of the other Party that the receiving Party becomes aware of in connection with the...

Страница 28: ...THIS DOCUMENT AT ANY TIME THE DATA AND INFORMATION SHOWN IN THIS CATALOGUE ARE SUBJECT TO CHANGE WITHOUT OBLIGATION TO GIVE PRIOR NOTICE BY CAME S P A E OE CAME BPT North Unit 1B Sills Road Willow Fa...

Отзывы: