+
_
DELAY 2M
OP. TIME
A.C.T.
ON
DIP
p.
9
- M
an
u
al
FA
0
0
67
9
-E
N
v.
1
- 1
2
/2
0
17 - © C
A
M
E S
.p.
A
. - T
h
e c
onte
nts of th
is
m
an
u
al
m
ay b
e c
h
an
g
ed, at a
ny ti
m
e, a
n
d w
ith
ou
t n
oti
ce
.
DIP-SWITCH
Description of functions
AUTOMATIC CLOSING
Automatic closing active (1 OFF - Deactivated)
OPEN-STOP-CLOSE-STOP
OPEN-STOP-CLOSE-STOP (sequential) function from control device (NO contact) and from
radio transmitter fitted with AF card.
OPEN-CLOSE-INVERT
OPEN-CLOSE-INVERT (step-step) function from control device (NO contact) and from radio
transmitter fitted with AF card.
SAFETY TEST
At each opening or closing command, the card checks whether the photocells are working
properly (3 OFF - Deactivated)
DELETING USERS
Deleting one or more users (4 OFF - Deactivated)
Settings
Functions
Trimmer
Description of functions
A.C.T.
AUTOMATIC CLOSING TIME
It sets the open gate's waiting time. Once this time elapses, a closing maneuver is automatically
performed.
The waiting time can be adjusted to between 1 and 120 seconds.
⚠
The automatic closing does not activate if the safety devices are triggered due to obstacle detection,
after a total Stop or if the current is missing.
OP. TIME
OPERATING TIME
This sets the gearmotors' operating time.
The operating time can be adjusted to between 15 and 120 seconds.
Setting the time to the minimum enables the maintained action function and disables the radio-
based controls.
DELAY 2M
MOTOR M2 CLOSING DELAY TIME
After a closing command or after an automatic closing, the leaf of gearmotor (M2) starts with a delay
compared to gearmotor (M1) for an adjustable time of between 3 and 10 seconds.
FUNCTIONS AND SETTINGS