background image

TITLE

7

 pre-installed

 sim card

The pre-installed SIM card is an IOT/M2M multi SIM complete with 480MB data allowance and 3 year life term. 
Under average usage of 3-4 gate manoeuvres per day, the data should last approximately 3 years.
In case you use up the 480MB data volume before the end of the 3-year term, you can easily add another 480MB data 
volume by making a top-up, details of which can be found here:

www.cameconnect.co.uk/gsmmodule

Due to situations outside of our control, CAME cannot guarantee signal strength or availability and therefore will not be 
held liable for lack of service.

came 

automation

internet

came 

cloud

setup app

for the installer

GET IT ON

App Store

GET IT ON

automation app

for the end user

GET IT ON

App Store

GET IT ON

System Frequency

Approx. Movements

Est. SIM Life Based on Usage

Occasional Usage

Approx. 5 gate manoeuvres per 

week

4-7 Years*

Average Usage**

Approx. 3-4 gate manoeuvres 

per day

3-4 Years

High Usage

Approx. 5+ gate manoeuvres per 

day, multiple scenarios running

1-3 Years

* SIM will expire after 3-4 years. (CAME guarantees 3 years with some tolerance for shelf life consideration)  

** We anticipate SIM provided will have suffi cient data for Average Usage (as shown above) lasting approx. 3 years   

8

 initial 

power ON

OUT1

OUT2

Keycode

123456789ABCDE F

MATR

54051 6

300mAE

GSM – 900  33dBm

DCS – 1800   30dBm

869.5MHz     14dBm  

24V

CONNECT

123

4

GND

A

N

T

10

+

2

COM

IN2

COM

IN1

B
A

 1A 30V

RGSM001S

1

2

1

     GSM LED (Blue)

    After a few seconds the LED will flash 1x/sec indicating the RGSM001S is registered on a GSM network.

2

     POWER LED (Green)

    The LED will flash 5x/sec indicating the RGSM001S is not yet configured on the Connect platform

Power on the control board.

to check motor direction using

 control panel

CAUTION, Ensure the gate movement area is clear of all obstructions

Check the motor direction  

A

 

2

 

 – 

O

 

N

 

 

For motor 2, Press and hold

 

 

The gate should open, if not reverse the motor cables for motor 2 (Connections M2, N2) 

 

Leave the gate leaf in the halfway position.

For motor 1, Press and hold

 

 

The gate should open, if not reverse the motor cables for motor 1 (Connections M1, N1) 
Leave the gate leaf in the halfway position.

Installer Tip 

 If the RGSM001S is located 

in a concealed area and a low 

GSM signal observed a 2m 

extension cable and bracket is 

available to purchase.

This then allows the aerial to 

be located in a more suitable 

position. Part No:

806SA-0050

Содержание ATS-P524

Страница 1: ...Typical gate setup geometry Gate motor manual release Kit wiring diagram Control panel guide safety Complete kit for a pair of swing gates weighing up to 400kg per leaf max width 5m TO BE READ IN CON...

Страница 2: ...SM001S Gateway Module RSE Connection Card SIM May be preinstalled in RGSM001S 1 Kit Contents 2 Safety Instructions 3 Typical Gate Setup 4 Geometry 5 Manual Release Instructions 6 Wiring Diagram 7 Pre...

Страница 3: ...ssing through the gate Keep feet away from the bottom of the gate during operation Do not operate the gate by remote control unless they are in view Do not attempt to block or interfere with the gate...

Страница 4: ...lands to connect the devices to the control panel One of these must be used exclusively for the power supply cable All holes should be sealed to avoid ingression and maintain the IP54 protection ratin...

Страница 5: ...F mm C max mm 90 200 200 1030 1430 150 90 200 270 1030 1510 200 120 200 140 1030 1460 70 Preliminary checks Side hung gate GEOMETRY 5m Tick 1 Check that the gate structure is sturdy enough the hinges...

Страница 6: ...refully at the same speed as the automatic operator 4 To re engage close the gate and turn the key back to its original position D Attempt to manually move the gate to ensure it is fully engaged Basic...

Страница 7: ...r to OFF TOP A433N Antenna Cable length RG58 Max 5m DIR Photocells Cable length RX 4 Core 0 5mm Flex TX 4 Core 0 5mm Flex 1m 30m 10 2 TX C NC TX 2 RX TX RGSM001S Gateway Module Cable length Max 3m pow...

Страница 8: ...rength or availability and therefore will not be held liable for lack of service came automation internet came cloud setup app for the installer GET IT ON AppStore GET IT ON automation app for the end...

Страница 9: ...ction using control panel CAUTION Ensure the gate movement area is clear of all obstructions Check the motor direction A 2 O N For motor 2 Press and hold The gate should open if not reverse the motor...

Страница 10: ...rrive please check your junk folder download the connect setup app adding the rgsm gateway to your technician account technician connect setup app 1 3 2 If you have an existing account please move to...

Страница 11: ...Bm 24V CONNECT 123 4 GND A N T 10 2 COM IN2 COM IN1 B A 1A 30V RGSM001S If you intend to retain control of the SIM for top up If as the installer you intend to retain control of the SIM for top up pur...

Страница 12: ...dd automation Select Manual Add Select ZL65 ZL65 from the drop down list Enter a name and description then press Add adding automation 1 ZL65 ZL65 Automation for swing gates Encoder Axo ATS M1 M2 Fron...

Страница 13: ...ition or Add with QR Code If you pressed Local Acquisition the screen will change to the one shown here Select the button on the fob and it will add the button straight onto the control panel Set the...

Страница 14: ...cess for all fobs Select the back button to return to the main menu If you select ADD via QR Code the app will open the devices camera enabling scanning of the QR code on the fobs packaging Once the Q...

Страница 15: ...n App On first login you will be prompted to accept the gateway You will then be presented with control options for your automation To transfer to a customer select the 3 dots Select Transfer site Ent...

Страница 16: ...te motor complete the following steps Send an opening command pulse using a link wire between terminal 2 7 While the motor is running turn the rod marked A clockwise until the motor stops running Note...

Страница 17: ...saved remove a transmitter button 1 Press and hold the button for 2 seconds to access programming F 1 appears on the display 2 Remove a transmitter button U 2 O N 3 Use the arrow buttons to choose the...

Страница 18: ...quire activation from a command device to restart C1 REOPENING DURING CLOSING When the automation is in its closing cycle and the safety circuit is triggered the automation will stop and reverse its m...

Страница 19: ...and fit the replacement SIM card into the slot Replace the casing and power up the control panel Send an SMS to the telephone number of the SIM reporting the APN details Access Point Name ask the serv...

Страница 20: ...colour 806SL 0240 SELB1SDG2 Surface mounted with blue backlighting for 50 users RAL7024 Grey colour 806SL 0250 SELB1SDG3 Surface mounted with blue backlighting for 250 users RAL7024 Grey colour TRANS...

Страница 21: ...tiple pairs of photocells can be applied to the same system even at double height and or close to each other with no interference issues cross talk 001DIR10 Pair of 12 24 V AC DC outdoor photocells ra...

Страница 22: ...correct use of the Software requires the possession of an automation home automation security temperature control and or video surveillance system manufactured by Came which has been enabled for remo...

Страница 23: ...ation of the automation home automation security temperature control and or video surveillance system manufactured by Came may be associated with the system itself In this way the installer can perfor...

Страница 24: ...immediate effect in the event of the violation of the terms of Articles 2 2 and or 2 5 In this case termination shall occur automatically upon receipt by the Installer of the notification sent by Came...

Страница 25: ...vidual parts of the additional network services and other related services referred to in Section 3 1 lit c of these GTC 1NCE expressly points out that the type and scope of such services of the respe...

Страница 26: ...tion 2 of these GTC for the Services Within the framework of the conclusion of the contract the Customer may choose between different payment methods offered by 1NCE Unless otherwise agreed between th...

Страница 27: ...a Protection Act Bundesdatenschutzgesetz 10 2The Parties also undertake to treat all other confidential information of the other Party that the receiving Party becomes aware of in connection with the...

Страница 28: ...THIS DOCUMENT AT ANY TIME THE DATA AND INFORMATION SHOWN IN THIS CATALOGUE ARE SUBJECT TO CHANGE WITHOUT OBLIGATION TO GIVE PRIOR NOTICE BY CAME S P A E OE CAME BPT North Unit 1B Sills Road Willow Far...

Отзывы: