background image

12 

SAFETY options

FUNCTIONS > CX Input, CY Input

SAFETY INPUTS

If during the reverse motion a diff erent safety is triggered the automation will perform the appropriate action for the new triggered 

safety, should multiple safeties be triggered at the same time the automation will be halted at its current position.

SENSITIVE EDGES

C7  

REOPENING DURING CLOSING

•  When the automation is in its closing cycle and the safety circuit is triggered the automation will reverse its motion until it reaches its fully open 

position again.

•  If the auto closing option is enabled and the safety is no longer triggered the auto closing countdown will commence, once completed the 

automation will start the closing cycle again.

•  If the auto closing option is not enabled the automation will return to the fully open position awaiting another activation from a command device.

C8  

RECLOSING DURING OPENING

•  When the automation is in its opening cycle and the safety circuit is triggered the automation will reverse its motion until it reaches its fully 

closed position again.

•  Once the automation has reached the fully closed position it will require another activation from a command device to restart.

The above sequence will be attempted 3 times before the automation is halted, the automation will then 

require activation from a command device to restart.

C1   

REOPENING DURING CLOSING

•  When the automation is in its closing cycle and the safety circuit is triggered the automation will stop and reverse its motion until it reaches its 

fully open position again.

•  If the auto closing option is enabled and the safety is no longer triggered the auto closing countdown will commence, once completed the 

automation will start the closing cycle again.

•  If the auto closing option is not enabled the automation will return to the fully open position awaiting another activation from a command device.

C2  

RECLOSING DURING OPENING

•  When the automation is in its opening cycle and the safety circuit is triggered the automation will stop and reverse its motion until it reaches its 

fully closed position again.

•  Once the automation has reached the fully closed position it will require another activation from a command device to restart.

C3  

PARTIAL STOP

•  When the automation is in its opening cycle and the safety circuit is triggered the automation will stop.

•  If the auto closing option is enabled and the safety is no longer triggered the auto closing countdown will commence, once completed the 

automation will start closing the device.

C4  

OBSTRUCTION WAIT

•  When the automation is in either its opening or closing cycle and the safety circuit is triggered the automation will stop.

•  Once the safety is no longer triggered the automation will carry on the cycle it was performing at the time it was interrupted.

13 

replacing the

 sim card

A third party SIM card may be used, for example, if an existing SIM card is available or the current SIM data contract 
expires.

To insert a SIM card please do the following:

With the power switched 

OFF

 to the control panel, remove the RGSM casing, slide out the existing SIM card and

fit the replacement SIM card into the slot. Replace the casing and power up the control panel.

Send an SMS to the telephone number of the SIM, reporting the APN details. Access Point Name – ask the service 
provider for APN details e.g. APN:pp.vodafone.co.uk  Capital, lowercase letters and punctuation must be respected 
The SIM must be capable of 2G data transmission and have the PIN code disabled.   

Full instructions for the RGSM001S module  
can be found be visiting:

https://docs.came.com/pdf/FA01289M4A.pdf

Содержание ATS-P524

Страница 1: ...Typical gate setup geometry Gate motor manual release Kit wiring diagram Control panel guide safety Complete kit for a pair of swing gates weighing up to 400kg per leaf max width 5m TO BE READ IN CON...

Страница 2: ...SM001S Gateway Module RSE Connection Card SIM May be preinstalled in RGSM001S 1 Kit Contents 2 Safety Instructions 3 Typical Gate Setup 4 Geometry 5 Manual Release Instructions 6 Wiring Diagram 7 Pre...

Страница 3: ...ssing through the gate Keep feet away from the bottom of the gate during operation Do not operate the gate by remote control unless they are in view Do not attempt to block or interfere with the gate...

Страница 4: ...lands to connect the devices to the control panel One of these must be used exclusively for the power supply cable All holes should be sealed to avoid ingression and maintain the IP54 protection ratin...

Страница 5: ...F mm C max mm 90 200 200 1030 1430 150 90 200 270 1030 1510 200 120 200 140 1030 1460 70 Preliminary checks Side hung gate GEOMETRY 5m Tick 1 Check that the gate structure is sturdy enough the hinges...

Страница 6: ...refully at the same speed as the automatic operator 4 To re engage close the gate and turn the key back to its original position D Attempt to manually move the gate to ensure it is fully engaged Basic...

Страница 7: ...r to OFF TOP A433N Antenna Cable length RG58 Max 5m DIR Photocells Cable length RX 4 Core 0 5mm Flex TX 4 Core 0 5mm Flex 1m 30m 10 2 TX C NC TX 2 RX TX RGSM001S Gateway Module Cable length Max 3m pow...

Страница 8: ...rength or availability and therefore will not be held liable for lack of service came automation internet came cloud setup app for the installer GET IT ON AppStore GET IT ON automation app for the end...

Страница 9: ...ction using control panel CAUTION Ensure the gate movement area is clear of all obstructions Check the motor direction A 2 O N For motor 2 Press and hold The gate should open if not reverse the motor...

Страница 10: ...rrive please check your junk folder download the connect setup app adding the rgsm gateway to your technician account technician connect setup app 1 3 2 If you have an existing account please move to...

Страница 11: ...Bm 24V CONNECT 123 4 GND A N T 10 2 COM IN2 COM IN1 B A 1A 30V RGSM001S If you intend to retain control of the SIM for top up If as the installer you intend to retain control of the SIM for top up pur...

Страница 12: ...dd automation Select Manual Add Select ZL65 ZL65 from the drop down list Enter a name and description then press Add adding automation 1 ZL65 ZL65 Automation for swing gates Encoder Axo ATS M1 M2 Fron...

Страница 13: ...ition or Add with QR Code If you pressed Local Acquisition the screen will change to the one shown here Select the button on the fob and it will add the button straight onto the control panel Set the...

Страница 14: ...cess for all fobs Select the back button to return to the main menu If you select ADD via QR Code the app will open the devices camera enabling scanning of the QR code on the fobs packaging Once the Q...

Страница 15: ...n App On first login you will be prompted to accept the gateway You will then be presented with control options for your automation To transfer to a customer select the 3 dots Select Transfer site Ent...

Страница 16: ...te motor complete the following steps Send an opening command pulse using a link wire between terminal 2 7 While the motor is running turn the rod marked A clockwise until the motor stops running Note...

Страница 17: ...saved remove a transmitter button 1 Press and hold the button for 2 seconds to access programming F 1 appears on the display 2 Remove a transmitter button U 2 O N 3 Use the arrow buttons to choose the...

Страница 18: ...quire activation from a command device to restart C1 REOPENING DURING CLOSING When the automation is in its closing cycle and the safety circuit is triggered the automation will stop and reverse its m...

Страница 19: ...and fit the replacement SIM card into the slot Replace the casing and power up the control panel Send an SMS to the telephone number of the SIM reporting the APN details Access Point Name ask the serv...

Страница 20: ...colour 806SL 0240 SELB1SDG2 Surface mounted with blue backlighting for 50 users RAL7024 Grey colour 806SL 0250 SELB1SDG3 Surface mounted with blue backlighting for 250 users RAL7024 Grey colour TRANS...

Страница 21: ...tiple pairs of photocells can be applied to the same system even at double height and or close to each other with no interference issues cross talk 001DIR10 Pair of 12 24 V AC DC outdoor photocells ra...

Страница 22: ...correct use of the Software requires the possession of an automation home automation security temperature control and or video surveillance system manufactured by Came which has been enabled for remo...

Страница 23: ...ation of the automation home automation security temperature control and or video surveillance system manufactured by Came may be associated with the system itself In this way the installer can perfor...

Страница 24: ...immediate effect in the event of the violation of the terms of Articles 2 2 and or 2 5 In this case termination shall occur automatically upon receipt by the Installer of the notification sent by Came...

Страница 25: ...vidual parts of the additional network services and other related services referred to in Section 3 1 lit c of these GTC 1NCE expressly points out that the type and scope of such services of the respe...

Страница 26: ...tion 2 of these GTC for the Services Within the framework of the conclusion of the contract the Customer may choose between different payment methods offered by 1NCE Unless otherwise agreed between th...

Страница 27: ...a Protection Act Bundesdatenschutzgesetz 10 2The Parties also undertake to treat all other confidential information of the other Party that the receiving Party becomes aware of in connection with the...

Страница 28: ...THIS DOCUMENT AT ANY TIME THE DATA AND INFORMATION SHOWN IN THIS CATALOGUE ARE SUBJECT TO CHANGE WITHOUT OBLIGATION TO GIVE PRIOR NOTICE BY CAME S P A E OE CAME BPT North Unit 1B Sills Road Willow Far...

Отзывы: