N.B.: The cable section, with diff erent lengths from those shown on the table, must be considered on the basis the actual draw of the
connected devices, according to what is prescribed in the CEI EN 60204-1 Code.
For connections that require varying loads on the same line (i.e. sequential), the table values should be reconsidered depending on
the actual draws and distances.
Connections
Type of cable
Length of cable
1 < 10 m
Length of cable
10 < 20 m
Length of cable
20 < 30 m
Control panel power supply 230V
FROR CEI
20-22
CEI EN
50267-2-1
3G x 1,5 mm
2
3G x 2,5 mm
2
3G x 4 mm
2
Motor power supply 230V
4G x 1 mm
2
4G x 1,5 mm
2
4G x 2,5 mm
2
Flashing light 24V
2 x 0,5 mm
2
2 x 1 mm
2
2 x 1,5 mm
2
Photocell transmitters
2 x 0,5 mm
2
2 x 0.5 mm
2
2 x 0,5 mm
2
Photocell receivers
4 x 0,5 mm
2
4 x 0,5 mm
2
4 x 0,5 mm
2
Accessories power supply 24V
2 x 0,5 mm
2
2 x 0,5 mm
2
2 x 1 mm
2
Control and safety devices
2 x 0,5 mm
2
2 x 0,5 mm
2
2 x 0,5 mm
2
Endpoints
3 x 0,5 mm
2
3 x 1 mm
2
3 x 1,5 mm
2
Antenna connection
RG58
max. 10 m
1) Gearmotor
2) Control panel
3) Radio receiver
4) Photocells
5) Keyswitch
6) Antenna
7) Flashing light
8) Transmitter
Cable list and minimum thickness
Standard installation