5 -
119RW90 ver. 2 11/2014
English
DESCRIPTION
001SDTCLWL is a radio-based curtain eff ect double-technology sensor;
integrating two passive infrared modules and one microwave module,
especially designed to obtain a very narrow detection beam to protect
windows and doors.
Its very small size makes it easy to install in confi ned spaces around
windows and doors. The alarm is generated only when both technologies
agree to detect intrusions. This prevents any false alarms. The sensor is
protected from removal, thanks to its own anti-rip out system.
Precautions
WARNING. The device runs on lithium batteries. Manage with care.
Danger of fi re and explosion. Do not throw out the batteries into a
fi re. Do not weld or damage the batteries. Respect their polarities.
To replace the batteries contact a SKILLED TECHNICIAN.
Dispose of exhausted batteries in compliance with the laws in eff ect,
even when decommissioning the device. If any liquid comes out,
protect your hands with special gloves.
The sensor must be only mounted horizontally, facing downwards and
above the opening to protect and covered from weather agents (keep
covered from pouring rain).
To avoid unwanted detections, do not use the sensor with mosquito
screens of any kind or with shutters that are not completely raised or
lowered (do not leave them partially raised). The sensor can detect
animal presence.
Technical data
Type
001SDTCLWL
Powered by 2 3 [V] lithium batteries
CR123A
Draw when standing by [uA]
<70
Draw while in alarm state [mA]
<70
Estimated eff ectiveness [years]*
2
DUAL-BAND radio transmission frequency [MHz]
868.65/433.92
Microwave operating frequency [GHz]
24
Max adjustable detection height [m]
3
Max detection width [m]
1.5 @ 3
Max detection depth [cm]
30 @ 300
Detection window [s]**
5
Shell
ABS, anti UV
* The estimated eff ectiveness of the sensor's battery in inversely propor-
tional to the number of detections it is subjected to (regardless of whether
the alarm system is armed or not). If the sensor is installed in areas with
high-fl ow rates, then the battery life could be drastically shortened.
** It is the time, starting from when an IR head detects, within which
also the second IR head must detect to activate the microwave and
establish and alarm.
Features
LED
LED
Color
Meaning
Red
Infrared 1
Green
Microwave
Red
Infrared 2
Blue
Transmission
Jumpers
JP1:
Tamper Enabling/disabling
JP1 OPEN:
tamper enabled
JP1 CLOSED:
tamper disabled
JP2:
LED Enabling/Disabling
JP2 OPEN:
LEDs disabled
JP2 CLOSED:
LEDs enabled
JP4:
Mode
JP4 OPEN:
Mode NORMAL
JP4 CLOSED:
Mode TEST
Infrared 1
Microwave
Infrared 2
Tamper
Power supply terminal
Dipswitch
DEFAULT
DIP1
ON
DIP WITCH 1 is exclusively for internal use, and MUST be
always set to ON
DIP2 (Sensitivity)
ON
Low sensitivity (window mounted)
OFF
High sensitivity (door mounted)
DIP3 (Transmission test )
ON
Transmission test enabled (transmits every second)
OFF
Normal operation
DIP4 Supervision
ON
Supervision enabled
OFF
Supervision disabled
Powering on
Before being powered up, the sensor must be set up as follows:
-
Dip1, Dip2, Dip3, Dip4
in position
OFF
;
-
JP1
open
,
JP2
closed
pay
JP4
closed
.
The settings must then be modifi ed with the power supply on
At this point the sensor is ready for
'initiation'
.
Initiation
By powering up the sensor, the BLUE LED (transmission)
fl ashes a few
times, then stays lit for a few moments and then turns off , whereas the
red LED (infrared 1 and 3) turn on and stay lit. The initiation will last about
two minutes, after which, the LEDs will fl ash a few times to confi rm this.