background image

Page 4 of 16

CX-EMF-2 MUL

TI-FUNC

TION TIMER

INST

AL

LA

TION INSTRUCTIONS

FILENAME:

EMF-2 Diagram 2.ai

D

R

AWING

 No:

 DRG-EMF-2_02

EMF-2 Diagram 2. Typical ABM Vestibule Application

SCAL

E:

  NON

E

D

R

AWN

 BY: 

D

G

W

RE

VI

SED

DATE:  

03

/24

/10

55

02

 T

im

be

rle

B

lv

d.

M

iss

is

sa

ug

a, O

ntar

io

L4

W

 2

T7

CA

M

DE

N D

OO

R C

O

NT

RO

LS

R

EL

AY

 5 Chart

To have Relay 5 shadow another rela

y,

set dipswitch

as shown:

D

ip

 4

OFF

OFF

1

2

3

4

OFF

ON

ON

ON

OFF

ON

D

ip

 5

=

Relay ON Indicators

In

si

de

W

al

l S

w

itc

h

O

ut

si

de

W

al

l S

w

itc

h

(o

pt

io

na

l)

Da

/ Ni

gh

t

Togg

le

 o

r

Ke

sw

itc

h

E

m

er

ge

nc

y

Pa

ni

S

w

itc

h

(o

pt

io

na

l)

M

agnetic Contact Switch

(only required if Panic switch  is utilised)

Fail-Safe Electric Strike Shown (if Fail-Secure lock is used,  wire to Terminals 1 & 2)

M

O

V

W

ire

 M

O

V

(s

up

pl

ie

d)

di

re

ct

ly

 to

 st

rike

or

 m

agne

t

P

ower for Strike

N

.C.

!

S

im

pl

M

ic

ro

-s

w

itc

h

ty

pe

 C

ar

rea

de

r

1

Ti

m

er

  S

ett

in

gs

EM

F-2

1

5

2

3

4

6

7

8

9

10

11

12

13

14

15

1

5

2

3

4

6

7

1

5

2

3

4

6

7

8

9

10

11

12

13

14

Off / O

n

1

2

5

7

4

6

3

8

M

od

e

R

el

 5

O

pt

2

3

4

5

LE

D

 O

ut

pu

t

12

V

5V

P

ow

er

O

N

N

C

N

C

N

C

N

C

N

C

N

O

N

O

N

O

N

O

N

O

C

C

C

C

C

R

el

ay

 1

R

el

ay

 2

R

el

ay

 3

R

el

ay

 4

R

el

ay

 5

1

2

12

/2

4V

Po

w

er

Inpu

ts

1

2

3

4

5

6

7

Di

gi

ta

l

 In

/O

ut

te

rm

ina

l

st

rip

O

ut

pu

t 1

P

ow

er

 +

5V

G

roun

1

B

ro

w

/ B

lu

e

Y

ell

ow

 / 

N

/C

O

ut

pu

t 2

G

roun

2

M

ag

-s

tri

pe

 s

ty

le

C

ar

rea

de

r

or

TO

 O

PE

N

PU

SH

TO

 O

PE

N

PU

SH

LO

C

K

ED

O

U

T

12

 - 

24

 V

A

C

/D

C

 P

ow

er

D

A

Y

N

IT

E

O

pt

io

na

l a

nd

 o

nl

if

P

an

ic

 s

w

itc

is

 u

til

iz

ed

Door Operator

Содержание CX-EMF-2

Страница 1: ...x 95mm In addition to the above Model EMF 2 ABM includes a lockable metal cabinet to house the relay The cabinet is equipped with two lighted push switches on to turn the relay power on or off and the...

Страница 2: ...op View P2 P3 P1 P4 Inputs Mode Rel 5 Opt Relay 1 Timer Settings Relay ON Indicators 7 6 5 4 3 2 1 NC C NO NC C NO NC C NO NC C NO NC C NO Relay 2 Relay 3 Relay 4 Relay 5 12 24V Power Trouble Output I...

Страница 3: ...1 2 of the Digital I O strip Re insert connector firmly if removed Connect 12 or 24V AC DC supply to terminals 1 2 of the 2 pin Power Connector Terminals are not polarity sensitive Step 4 Adjustments...

Страница 4: ...quired if Panic switch is utilised Fail Safe Electric Strike Shown if Fail Secure lock is used wire to Terminals 1 2 MOV Wire MOV supplied directly to strike or magnet Power for Strike N C Simple Micr...

Страница 5: ...ollowing connections Wire all input connections to the removable Input terminal strip numbered 1 14 Firmly re insert connector if removed Next make your connections to the Relay Output strip numbered...

Страница 6: ...inals 1 2 Wire MOV supplied directly to strike or magnet Power for Strike Door Operator Inside Wall Switch Outside Wall Switch Occupied LED optional Panic switch optional Inside Push to Lock Switch 12...

Страница 7: ...and all connected equipment strike lights etc Observe the red Power LED on the unit which should light If not re confirm proper voltage and or terminal strip connection Enter keypad key switch or othe...

Страница 8: ...ke or magnet Power for Strike Occupied LED optional Inside Wall Switch Outside Wall Switch optional Panic switch optional Inside Push to Lock Switch 12 24 V AC DC Power Magnetic Contact Switch MOV PUS...

Страница 9: ...es 4 5 See diagram 1 for location A common use in this mode would be that Relay 5 follows the lock relay and lights an occupied sign It could also be utilized for the second door lock rather than conn...

Страница 10: ...Occupied LED optional Inside Wall Switch Door 1 Outside Wall Switch Door 1 Panic switch optional 12 24 V AC DC Power Magnetic Contact Switch on both doors Wire in series PUSH TO LOCK Door 1 Lock Opti...

Страница 11: ...t A is activated first door A opens then when closed again door B opens in sequence Conversely when input B is activated first door B opens then when it is closed again door A opens sequentially A thi...

Страница 12: ...EN PUSH TO OPEN PUSH N C N C 1 Timer Settings Relay On Indicators EMF 2 1 5 2 3 4 6 7 8 9 10 11 12 13 14 15 1 5 2 3 4 6 7 1 5 2 3 4 6 7 8 9 10 11 12 13 14 Off On 1 2 5 7 4 6 3 8 Mode Rel 5 Opt 2 3 4 5...

Страница 13: ...provides a trouble output on pins 6 7 after 5 minutes of door ajar Connect 12 or 24V AC DC supply to terminals 1 2 of the 2 pin Power Connector Terminals are not polarity sensitive Step 4 Adjustments...

Страница 14: ...5 Contact Power for Strike Power for Strike Power for Strike Power for Strike Power for Strike Trouble output after 5 minutes of door ajar Select 5V or 12V output with jumper 12 24 V AC DC Power Troub...

Страница 15: ...nd or terminal strip connection Activate an input device to one of the doors Observe the respective output LED which should light immediately The door should unlock and or open If a request to open co...

Страница 16: ...Door 2 Lock TO OPEN PUSH Inside Wall Switch Door 2 LOCK DOWN N C N C Trouble Trouble output after 5 minutes of door ajar Select 5V or 12V output with jumper STEP HERE ONLY Trouble Output 1 Timer Setti...

Отзывы: